PWR SUPPLY TRPL 5/15/-15V 40W

LPT45

Manufacturer Part NumberLPT45
DescriptionPWR SUPPLY TRPL 5/15/-15V 40W
ManufacturerEmerson Network Power
SeriesLPT40
LPT45 datasheet
 

Specifications of LPT45

Voltage - Output5V, ±15VNumber Of Outputs3
Power (watts)40WApplicationsCommercial
Power Supply TypeSwitching (Open Frame)Voltage - Input85 ~ 264VAC
Mounting TypeChassis Mount1st Output5 VDC @ 4A
2nd Output15 VDC @ 2A3rd Output-15 VDC @ 500mA
Size / Dimension5" L x 3" W x 1.14" H (127mm x 76.2mm x 29mm)Power (watts) - Rated40W
Operating Temperature0°C ~ 50°CEfficiency70%
ApprovalsCB, CE, CSA, NEMKO, ULLine Regulation±2%, ±5%
Load Regulation±2%, ±5%Output Power Rating20 W
Input Voltage85 VAC to 264 VACOutput Voltage (channel 1)5 V
Output Current (channel 1)4 AOutput Voltage (channel 2)15 V
Output Current (channel 2)2 AOutput Voltage (channel 3)- 15 V
Output Current (channel 3)0.5 AMounting StyleChassis
Dimensions5 in L x 3 in W x 1.14 in HLead Free Status / RoHS StatusLead free / RoHS Compliant
4th Output-Other names454-1081
1
Page 1
2
Page 2
3
Page 3
Page 1/3

Download datasheet (581Kb)Embed
Next
LPT40 Series
40 Watts
Total Power:
40 - 55 Watts
Input Voltage:
85 - 264 VAC
120 - 300VDC
# of Outputs:
Triple
Special Features
• Universal input
• 3” x 5” footprint
• Less than 1U high
• Remote sense on main output
• Terminal Block option (-T)
• Built-in EMI filter
• Low output ripple
• Adjustable main output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX40 enclosure kit available
Safety
UL
UL60950
E132002
CSA CSA 22.2-234 Level 3
LR53982C
NEMKO EN 60950/EMKO-TUE
P95100411
(74-sec) 203
CB
Certificate and report
1118, 1122, 1123, 1124
Mark (LVD)
CE
Electrical Specifications
Input
8 5-264 VAC
Input range:
120-300 VDC
Frequency:
47-440 Hz
Inrush current:
< 18 A peak @ 115 VAC;
< 36A peak @ 230 VAC, cold start @ 25 °C
Input current:
1A max. (RMS) @ 115 VAC
Efficiency:
70% typical at full load (60% for LPT41)
EMI:
F CC Class B conducted; CISPR 22 Class B conducted
EN55022 Class B conducted;
VDE 0878 PT3 Class B conducted
Safety ground
< 0.5 mA @ 50/60 Hz, 264 VAC input
leakage current:
Output
40W for convection (LPT41, 25W);
Maximum Power:
55W with 30CFM forced air (LPT41, 41W)
Cross regulation:
± 2% on output 1; ±5% on outputs 2, 3
Adjustment range:
-5, +10% minimum
20ms @ 40W load, 115 VAC nominal line
Hold-up time:
S hort circuit protection on all outputs. Case overload
Overload protection:
protected @ 110% to 145% above peak rating
5.7 to 6.7 VDC on the main output
Overvoltage protection:
LPT41: 3.6 to 4.6VDC
Remote sense:
Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 2.16.09_164
LPT40 Series
1 of 3

LPT45 Summary of contents

  • Page 1

    LPT40 Series 40 Watts Total Power Watts Input Voltage 264 VAC 120 - 300VDC # of Outputs: Triple Special Features • Universal input • 3” x 5” footprint • Less than 1U high • Remote sense on main output • Terminal Block option (-T) • Built-in EMI filter • Low output ripple • Adjustable main output • Overvoltage protection • Overload protection • ...

  • Page 2

    ... LPT42(-T) +5V 0.4A +12V 0.2A -12V 0A LPT43(-T) +5V 0.5A +12V 0A -12V 0A LPT44(-T) +5V 0.4A +12V 0.2A -5V 0A LPT45(-T) +5V 0.4A +15V 0.2A -15V 0A LPT46(-T) +5V 0.4A +24V 0.1A +12V 0A LPT47(-T) +5V 0.4A +24V 0.2A -12V 0A 1. Peak current lasting < 30 seconds with a maximum 10% duty cycle °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. ...

  • Page 3

    ... Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25 °C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.5lbs/0.23kg Remote Sense M2 Connector SK201 _ + Voltage Adj. Pot 0.15" (4) DIA (4 places) LPT44 LPT45 LPT46 LPT47 Line Line Line Line Neutral Neutral Neutral Neutral +12V +15V +24V +24V +5V +5V +5V +5V +5V +5V +5V +5V ...