NPS42-M Emerson Network Power, NPS42-M Datasheet

POWER SUP MED&ITE 5V 45W 2"X4"

NPS42-M

Manufacturer Part Number
NPS42-M
Description
POWER SUP MED&ITE 5V 45W 2"X4"
Manufacturer
Emerson Network Power
Series
NPS40-Mr
Datasheet

Specifications of NPS42-M

Voltage - Output
5V
Number Of Outputs
1
Power (watts)
60W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 8A
Size / Dimension
4" L x 2" W x 1" H (101.6mm x 50.8mm x 25.4mm)
Power (watts) - Rated
45W
Operating Temperature
0°C ~ 80°C
Efficiency
87%
Approvals
CB, CE, CSA, NEMKO, TUV, UL
Line Regulation
±2%
Load Regulation
±2%
Commercial/medical
Both
Output Power Rating
40 W, 60 W
Input Voltage
90 VAC to 264 VAC, 127 VDC to 300 VDC
Output Voltage (channel 1)
5 V
Output Current (channel 1)
8 A
Mounting Style
Chassis
Dimensions
2 in L x 4 in W x 0.86 in H
Open Frame/enclosed
Open Frame
Output Type
DC
Output Current (max)
8A
Output Voltage
5V
Output Power (max)
40W
Input Frequency
47 to 440Hz
Screening Level
Commercial
Product Length (mm)
101.6mm
Product Height (mm)
25.4mm
Product Depth (mm)
50.8mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Pin Count
8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
NPS40-M Series
60 Watts
Special Features
• Medical and ITE Safety Approvals
• Universal input
• Less than 1U high
• 2” x 4” footprint
• Remote sense
• Overload and short circuit
• Adjustable output voltage
• High efficiency
• High MTBF
• Built in EMI filter
• International Efficiency Level V,
• Less than 300 mW no-load
• 0˚C to +80˚C operation
• Input power < 74 watts
• Complies with EN61000 -3-2
• UL Class I approved
• LPX50 enclosure kit available
Safety
Total Power:
Input Voltage:
# of Outputs:
protection
(CISPR 22 Class B)
Energy Star 2.0 & CeC compliant
(except NPS42-M)
power consumption
TUV: 60950, 60601-1
UL:
CSA: 60950, 60601-1
NEMKO: 60950, 60601-1
CB:
CE:
60950, 60601-1
Mark (LVD)
Certificate and report
45 - 60 Watts
90 - 264 VAC
127 - 300 VDC
Single
Electrical Specifications
Input
Input range:
Frequency:
Inrush current:
Input power:
Efficiency:
EMI/RFI:
Safety ground leakage
current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection: 30-50% above nominal output
Remote sense:
90 - 264 VAC (wide range) 127-300 Vdc
47-440 Hz
< 50 A peak @ 230 VAC, cold start @ 25° C
< 74 Watts
87% average (as per Energy Star 2.0 standard)
FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B
conducted, VDE0878PT3 Class B conducted
275uA @ 50/60 Hz; 264 VAC input
45W for convection (40W for NPS42-M). 60 W with 200LFM forced air
(55 Watts for NPS42-M)
±20% minimum
10/ 2 0 ms 115/230 VAC input line
Short circuit protection on all outputs. Case overload protected @
110-160% of normal rating
Compensated for 0.5 V lead drop max. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 9.15.09_163
NPS40-M Series
1 of 3

Related parts for NPS42-M

NPS42-M Summary of contents

Page 1

... EMI/RFI: FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted, VDE0878PT3 Class B conducted Safety ground leakage 275uA @ 50/60 Hz; 264 VAC input current: Output Maximum power: 45W for convection (40W for NPS42-M with 200LFM forced air (55 Watts for NPS42-M) Adjustment range: ±20% minimum Hold-up time: 10 115/230 VAC input line Overload protection: Short circuit protection on all outputs. Case overload protected @ 110-160% of normal rating Overvoltage protection: 30-50% above nominal output Remote sense: Compensated for 0.5 V lead drop max. Will operate without remote sense connected ...

Page 2

Environmental Specifications Operating temperature: 0° °C ambient derate each output as 2.5% per degree from 50° °C. -20 °C start up Storage temperature: -45 °C to +85 °C Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 10% to 90% RH Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated: > 550,000 hours at full load and 25 °C ambient conditions Mechanical Drawing BARCODE M1 GND TAB (CN1) PIN 1 PIN 3 INPUT CONNECTOR (SK1) 0.16” (4.0) MOUNTING HOLE (4 PLACES) 0.197” (5.0) MINIMUM STANDOFF HEIGHT 4.00" (101.6) 3.73" ...

Page 3

... NPS42 NPS43 NPS44 NPS45 NPS48 Peak current lasting < 15 seconds with a maximum 10% duty cycle °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. Pin Assignments NPS42-M NPS43-M Connector SK1-1 Line Line SK1-3 Neutral Neutral SK2 +12 V SK2 +12 V SK2-3 Common Common SK2-4 Common ...

Related keywords