NLP150L-96S8 Emerson Network Power, NLP150L-96S8 Datasheet - Page 3

no-image

NLP150L-96S8

Manufacturer Part Number
NLP150L-96S8
Description
PS SWITCHER UNIVERSAL 24V 110W
Manufacturer
Emerson Network Power
Series
NLP150Lr
Datasheet

Specifications of NLP150L-96S8

Rohs Status
RoHS non-compliant
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
150W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 4.6A
Size / Dimension
3.8" L x 6.8" W x 1.26" H (96.5mm x 172.7mm x 32mm)
Power (watts) - Rated
110W
Operating Temperature
0°C ~ 50°C
Efficiency
73%
Approvals
CSA, UL, VDE
Line Regulation
±2%
Load Regulation
±2%
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NLP150L-96S8
Manufacturer:
ARTESYN
Quantity:
1 000
Part Number:
NLP150L-96S8J
Manufacturer:
ARTESYN
Quantity:
1 000
Specifications Contd.
1
2
3
4
5
6
7
8
9
10 Conducted EMI specifications reference measurements made with the power
11 All models require a minimum mounting stand-off of 6.35 mm (0.25 inches) in
12 The ‘Y’ suffix indicates that these parts are non Pb-free (RoHS 5/6) compliant.
13 NOTICE: Some models do not support all options. Please contact your local
Notes
12 V, iso (V
Free air convection.
Multiple output units: maximum continuous output power not to exceed 110
W and the output current not to exceed: I
300 LFM forced air cooling from the longer side.
Multiple output units: maximum continuous output power not to exceed 150
W and the output current not to exceed: I
Peak output current lasting less than 30 seconds with duty cycle less than 5%.
During peak loading, output voltage may exceed total regulation limits.
Figure is peak-to-peak for room temperature rating. Output noise
measurements are made across a 20 MHz bandwidth using a 6 inch twisted
pair, terminated with a 10 μF electrolytic capacitor and a 0.1 μF ceramic
capacitor.
Minimum load required for correct start-up and operation on single outputs
and on main output of multiple versions. Failure to observe minimum load on
main output will not allow the supply to start-up correctly. Some electronic test
loads have a large delay time before they start drawing current even though the
voltage from the supply is present. During this time delay, there is no load on
the output and as a result, the supply may not be able to start-up properly and
maintain its correct output voltage. In these instances, a dummy resistive load
across the output may be necessary to load the output of the supply until the
test load can function correctly and draw the intended minimum load.
Minimum load required on auxiliary outputs to maintain regulation.
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5
Hz to 500 Hz.
For optimum reliability no part of the heatsink should exceed 110 °C and no
semi-conductor case temperature should exceed 120 °C.
CAUTION: Allow a minimum of 1 second after disconnecting line power when
making thermal measurements.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
supply mounted on a grounded metal sheet extending 1 inch beyond each
edge, using an unshielded cable. No external filtering required during
conducted emissions testing but some applications may require additional
filtering to achieve system compliance. Compliance with Radiated EMI
specifications may require mounting in a suitable enclosure.
the end use product.
RoHS 6/6 (Pb-free) compliant versions are also available by replacing the suffix
‘Y’ with the suffix ‘J’ e.g. NLP150L-96Q5366J.
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
+3.3 V (V
+12 V (V
5.1 V (V
VOLTAGE
OUTPUT
A
C
B
)
)
D
)
)
MIN
1.5 A
0.5 A
0 A
0 A
(5)
OUTPUT CURRENT
A
A
+I
+I
B
B
+2(I
+2(I
MAX
0.65 A
20 A
10 A
C
C
2 A
+I
+I
D
D
(1)
)≤23 A.
)≤32 A.
300 LFM
30 A
15 A
3 A
1 A
(2)
150W
110W
0°C
RIPPLE
DERATING CURVE
Output Power (Watts)
120 mV
120 mV
50 mV
50 mV
10°C 20°C 30°C 40°C 50°C 60°C 70°C
(4)
300 LFM FORCED
AIR COOLING
CONVECTION
NATURAL
COOLING
REGULATION
TOTAL
±2.0%
±2.0%
±5.0%
±5.0%
Embedded Power for
Business-Critical Continuity
NLP150L-96Q5366Y
NUMBERS
MODEL
(12,13)
75W
55W
NLP150L Series
Rev.02.20.07
3 of 5

Related parts for NLP150L-96S8