HTD1 TDK Corporation, HTD1 Datasheet

no-image

HTD1

Manufacturer Part Number
HTD1
Description
PWR SUP TRIPLE 5V +12V -12V
Manufacturer
TDK Corporation
Series
Hr
Type
Commercialr
Datasheets

Specifications of HTD1

Voltage - Output
5V, ±12V
Number Of Outputs
3
Power (watts)
70W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
100, 120, 220, 230, 240VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 6A
2nd Output
12 VDC @ 1.7A
3rd Output
-12 VDC @ 1.7A
Size / Dimension
11.02" L x 4.88" W x 2.76" H (280mm x 124mm x 70mm)
Power (watts) - Rated
70W
Operating Temperature
0°C ~ 70°C
Approvals
CE, EN, UL
Line Regulation
±0.05%
Load Regulation
±0.05%
Brand/series
H Series
Configuration
Open-Frame
Dimensions
4.881 in. L x 11.023 in. W x 2.755 in. H
Frequency, Input
47 to 63 Hz
Operation
Linear
Output
-12/15 VDC @ 1.7/1.5 A, 5 VDC @ 6 A, +12/15 VDC @ 1.7/1.5 A
Output Type
Triple
Power, Output
70.0 W
Primary Type
AC-DC
Special Features
Remote Sense
Standards
UL Listed, CSA Certified, CE Marked
Temperature, Operating
0 °C
Voltage, Input
100, 120, 220, 230, 240 VAC
Voltage, Output
-12/15, 5, +12/15 VDC
Voltage, Output 1
5 V
Voltage, Output 2
+12⁄15 V
Voltage, Output 3
-12⁄15 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
** Important Note
Before connecting AC power to the H Series, please verify that the power transformer is
correctly terminated as detailed section 6. Failure to do so could damage the power
supply.
Installation
1) Power Supply Terminals
2) Service Personnel
3) Earthing
4) Cooling
5) Remote sensing
6) Input connection
To meet safety requirements, the power supply terminals must not be used as the
external terminations of any equipment. The wiring of any primary circuitry should
be routed in such a way that it does not touch any secondary (output) components.
This product must only be installed in a restricted access location, accessible to
authorized competent personnel only. Some surfaces of the power supply may be
hot, and must not be touched when the product is in operation.
For protective earthing, please ensure a secure connection of the Frame Ground
terminal to the ground terminal of the equipment as the protective earth connection.
Screws and washers used must be of a suitable material as defined by the relevant
agency specifications.
The power supply must be installed where the unit is allowed free air convection.
Forced air-cooling will enhance reliability.
Some models have remote sensing to compensate for load cable drops. The H
Series units come wired for local sense from the factory. Remove the wire jumpers
and install remote sense wiring if load regulation is critical.
Remote sense wiring to the end load should ideally be twisted together and routed
separately from load cables or other noisy wiring.
The AC power is wired directly to the primary of the main power transformer. One or
two jumpers will also needed on that transformer. Connect the AC Line & Neutral
and jumper(s) as follows:
Installation Instructions – H Series
LAMBDA
HSeries

Related parts for HTD1

HTD1 Summary of contents

Page 1

Important Note Before connecting AC power to the H Series, please verify that the power transformer is correctly terminated as detailed section 6. Failure could damage the power supply. Installation 1) Power Supply Terminals To meet ...

Page 2

AC INPUT & JUMPER INFORMATION For use at: 100VAC Jumper( Apply L & fuse An external fuse (see ratings table) should be installed. Use a 125VAC or ...

Page 3

Solder the black lead to the – lead of the supply and the white lead to the + output of the supply. Double check to be sure that the + output of the supply is connected to the + lead ...

Page 4

Under all conditions, removal of input power is necessary to reset the OVP Marking The CE Marking on the product is applied to show conformance to the requirements outlined in the European Union’s Low Voltage Directive [72/73/EEC] are ...

Page 5

... HDB-12-15 0.72/0.6 2.4 1.4 80 HDC12 2.4 1.4 2.1 1.2 80 HDC15 2.1 1.2 2.1 1.2 40 HTC1 0.4/0.32 0.4/0.32 4.2 2.8 70 HTD1 0.68/0.6 0.68/0.6 OVP12 HSeries LAMBDA Model Case Size AC Input Fusing 110V A 0.5A B 1.5A C 1.5A I 2.0A A 0.5A B 1.5A C 1. ...

Page 6

AC Input EMI Leakage Current Output Voltage Adjustment Line Regulation Load Regulation Output Ripple Transient Response Temperature Coefficient Operating Temperature Range Storage Temperature Range Operating Humidity Cooling Over Voltage Protection Over Current Protection Efficiency (Typical) Remote Sensing Warranty Agency Approvals ...