HTD1 TDK Corporation, HTD1 Datasheet - Page 3

no-image

HTD1

Manufacturer Part Number
HTD1
Description
PWR SUP TRIPLE 5V +12V -12V
Manufacturer
TDK Corporation
Series
Hr
Type
Commercialr
Datasheets

Specifications of HTD1

Voltage - Output
5V, ±12V
Number Of Outputs
3
Power (watts)
70W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
100, 120, 220, 230, 240VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 6A
2nd Output
12 VDC @ 1.7A
3rd Output
-12 VDC @ 1.7A
Size / Dimension
11.02" L x 4.88" W x 2.76" H (280mm x 124mm x 70mm)
Power (watts) - Rated
70W
Operating Temperature
0°C ~ 70°C
Approvals
CE, EN, UL
Line Regulation
±0.05%
Load Regulation
±0.05%
Brand/series
H Series
Configuration
Open-Frame
Dimensions
4.881 in. L x 11.023 in. W x 2.755 in. H
Frequency, Input
47 to 63 Hz
Operation
Linear
Output
-12/15 VDC @ 1.7/1.5 A, 5 VDC @ 6 A, +12/15 VDC @ 1.7/1.5 A
Output Type
Triple
Power, Output
70.0 W
Primary Type
AC-DC
Special Features
Remote Sense
Standards
UL Listed, CSA Certified, CE Marked
Temperature, Operating
0 °C
Voltage, Input
100, 120, 220, 230, 240 VAC
Voltage, Output
-12/15, 5, +12/15 VDC
Voltage, Output 1
5 V
Voltage, Output 2
+12⁄15 V
Voltage, Output 3
-12⁄15 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Solder the black lead to the – lead of the supply and the white lead to the + output of
the supply. Double check to be sure that the + output of the supply is connected to
the + lead of the OVP module and the – output is connected to the – lead. Rotate the
potentiometer (R1) on the OVP module completely clockwise. Without having your
load connected to the supply, apply power to the supply and adjust the output
voltage on the supply, to the level at which you wish the OVP to trigger. Slowly
adjust R1 on the OVP module counterclockwise to the point at which the output of
the supply drops suddenly. The OVP trip level is now set. Remove input power to
the power supply and back the voltage adjust potentiometer slightly. Re-energize the
supply and adjust the output voltage to the nominal voltage rating. The OVP trip
level is now set. You may wish to set the OVP potentiometer in place with an
electrical grade varnish such as glyptol.
Your load is now protected against an overvoltage condition that could destroy the
load.
Should you experience a situation where the OVP triggers, remove input power!
Check for any failures.
If the input fuse to the power supply is blown, it is a good indication that there is a
failure to the power supply itself.
If you find that there is no failure, re-energize the supply. If the supply voltage
returns to nominal, the power supply and OVP will be ready for another OVP
situation. This is called a nuisance trip. It is not uncommon and does not indicate a
failure of the OVP module. Instead, it has done its job and protected your circuit.
Nuisance tripping is generally caused by voltage spikes created by the load. If it
continually occurs, check your load for noise generating conditions and correct them.