MTC600-48RR16S9J Emerson Network Power, MTC600-48RR16S9J Datasheet - Page 10

no-image

MTC600-48RR16S9J

Manufacturer Part Number
MTC600-48RR16S9J
Description
MODULE POWER 600W 48VIN 16CH
Manufacturer
Emerson Network Power
Series
MTC600r
Type
Isolatedr
Datasheet

Specifications of MTC600-48RR16S9J

Output
3.3V, 12.95V
Number Of Outputs
2
Power (watts)
600W
Mounting Type
Rack Mount
Voltage - Input
48V
Package / Case
Module
1st Output
12.95 VDC @ 7.6A
2nd Output
3.3 VDC @ 250mA
Size / Dimension
7.37" L x 2.34" W x 2.89" H (187.2mm x 59.44mm x 73.4mm)
Power (watts) - Rated
600W
Operating Temperature
-5°C ~ 45°C
Approvals
CSA, CUL, UL, VDE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1307
IPMB-0 Interface
PM-EMMC
Supported Commands
Functionality
A PM-EMMC is implemented per MicroTCA.0 R1.0 requirements 4.116 through 4.120
IPM Device
IPMB Interface
SDR Repository
Sensors
Watchdog Timer
FRU Inventory
Initialization Agent
Internal Event Generation
External Event Generation
Power Channel Mapping
Global Commands
NetFN App Request=06h; Response=07h
Command
Get Device ID
Cold Reset
Event Commands
NetFN S/E Request=04h; Response=05h
Command
Set Event Receiver
Get Event Receiver
Platform Event
Power Channel
5-16
1, 2
3, 4
MP_CU1, MP_CU2
MP_M1, MP_M2
MP_1 - MP_12
Management
Power
PM-EMMC aggregates IPMB-A and IPMB-B IPMI v1.5 protocol
Implements mandatory 2 temp sensors; Implements voltage and current senors
Implements a watchdog timer for resetting PM's own PM-EMMC
PM-EMMC is responsible for initializing it's own event generation and sensors
Events sent over IPMB-0
PP_CU1, PP_CU2
Payload Power
PP_M1, PP_M2
PP_1 - PP_12
CMD
CMD
01h
02h
00h
01h
02h
PS1_CU1#, PS1_CU2#
PS1_M1#, PS1_M2#
PS1_# - PS1-12#
As defined in IPMI v1.5; Broadcast Get Device ID not supported
PS1#
As defined in IPMI v1.5
As defined in IPMI v1.5
As defined in IPMI v1.5
As defined in IPMI v1.5
EN_CU1#, EN_CU2#
EN_M1#, EN_M2#
EN_1# - EN_12#
ENABLE#
Note
Note
Embedded Power for
Business-Critical Continuity
Depends on PWRON_
Autonomous Power
M1, PWRON_M2
Yes
No
MTC600 Series
Rev. 05.26.08
10 of 19

Related parts for MTC600-48RR16S9J