AD10048P3L-001 Emerson Network Power, AD10048P3L-001 Datasheet

POWER SUPPLY AC/DC 48V 100W

AD10048P3L-001

Manufacturer Part Number
AD10048P3L-001
Description
POWER SUPPLY AC/DC 48V 100W
Manufacturer
Emerson Network Power
Datasheet

Specifications of AD10048P3L-001

Form
Desktop (3 Prong without Cord)
Voltage - Output Per Connector
48VDC
Current - Output
2.08A
Voltage - Input
90 ~ 264VAC
Power - Output
100W
Transformer Type
Switching - Energy Star
Efficiency
90%
Mounting Style
Desktop
Input Voltage (nominal)
90 VAC to 264 VAC
Number Of Outputs
1
Output Power Rating
100 W
Output Voltage (channel 1)
48 V
Output Current (channel 1)
2.08 A
Dc Output Connector
2.5 mm Barrel Plug
Dc Output Cord Length
1500 mm
Ac Plug Included/required
Required
Commercial/medical
Commercial
Power Supply Output Type
Fixed
Power Rating
100W
Input Voltage
90V AC To 264V AC
Supply Voltage Typ
110V AC / 230V AC
Output Voltage
48V
Output Current
2.08A
Power Supply Mounting
Desktop
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Polarization
-
Cord Plug
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1250
AD10048P3L-001
100 Watts
Special Features
• Active power factor correction
• EN6100-3-2 compliant
• CE Mark EMC & LVD
• Universal ac input
• Fully regulated output
• Overcurrent, overvoltage
• Constant voltage
• Level V efficiency
• High MTBF
• IEC320 ac receptacle, 3 pin
• Built in EMI filter
• (CISPR 22 Class B)
• AC Input fuse
• Complies with One Watt Input
• POE isolation on output
Safety
• UL
• CSA
• NEMKO EN/IEC60950-1
• CB
Total Power:
Input Voltage:
# of Outputs:
and thermal protection
(type C6)
Energy Star / Blue Angel
requirement
CSA-C22.2 no.60950-1
UL 60950-1
Certificate and report
100 Watts
90 - 264 Vac
Single
Electrical Specifications
Environmental Specifications
Input
Input ra n ge:
Frequency:
Inrush current:
Input current:
Efficiency:
EMI/RFI:
Safety ground
leakage current:
Output
Maximum Power (Po):
Hold-up time:
Overvoltage protection: 53 - 60 V
Overcurrent protection:
Thermal protection:
Cable/connector:
Operating temperature:
Storage temperature:
Electromagnetic
susceptibility:
Humidity:
MTBF demonstrated:
90 - 264 Vac (wide range)
47 - 63Hz
40 A maximum @ 264 Vac, cold start 25 °C
1.8 A maximum
90% typical
FCC Part 15, Subpart B Class B & EN55022 (CISPR 22) Class-B
3.5 mA maximum @ 50/60 Hz, 264 Vac input
100 W
10 ms. minimum at full load @ 115 Vac
Latching type, recycle ac to reset
Output short circuit protection auto recover
Overload protection @ 110 - 120% above maximum rating
105 °C to 120 °C Trip point; output will latch off
DC cable length 2.5 mm center plug
DC plug center +v
DC plug outer -v
0 ° to + 45 °C ambient
- 40 °C to + 70 °C
Designed to meet EN61000-4-2, -4, -5, level 4;
EN61000-4-3, -6, 10v/m; EN61000-4-8, -11; EN61000-3-3
and EN61000-3-2 Class A
Operating; non-condensing 5% to 90% RH
> 300,000 hours at full load and 25 °C ambient conditions
Embedded Power for
Business-Critical Continuity
Rev. 03.16.11_14
AD10048P3L-001
1 of 2

Related parts for AD10048P3L-001

AD10048P3L-001 Summary of contents

Page 1

... Cable/connector: DC cable length 2.5 mm center plug DC plug center +v DC plug outer -v Environmental Specifications Operating temperature: 0 ° °C ambient Storage temperature ° °C Electromagnetic Designed to meet EN61000-4-2, -4, -5, level 4; susceptibility: EN61000-4-3, -6, 10v/m; EN61000-4-8, -11; EN61000-3-3 and EN61000-3-2 Class A Humidity: Operating; non-condensing 5% to 90% RH MTBF demonstrated: > 300,000 hours at full load and 25 °C ambient conditions Embedded Power for Business-Critical Continuity Rev. 03.16.11_14 AD10048P3L-001 ...

Page 2

... Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2011 Emerson Electric Co. Rev. 03.16.11_14 AD10048P3L-001 ...

Related keywords