HS1527ECH61H Renesas Electronics America, HS1527ECH61H Datasheet

no-image

HS1527ECH61H

Manufacturer Part Number
HS1527ECH61H
Description
DEV EMULATOR PCB ADAPTOR FP-100M
Manufacturer
Renesas Electronics America
Datasheet

Specifications of HS1527ECH61H

Accessory Type
User Interface Cable
For Use With/related Products
H8SX/1527
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
To our customers,
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Renesas Electronics website:
Old Company Name in Catalogs and Other Documents
http://www.renesas.com
April 1
Renesas Electronics Corporation
st
, 2010

Related parts for HS1527ECH61H

HS1527ECH61H Summary of contents

Page 1

To our customers, Old Company Name in Catalogs and Other Documents st On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the ...

Page 2

All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm ...

Page 3

... H8SX/1520 Group FP-100M User System Interface Cable User’s Manual Renesas Microcomputer Development Environment System HS1527ECH61H Rev.1.00 2005.01 ...

Page 4

Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead ...

Page 5

... The HS1527ECH61H is a user system interface cable that connects an H8SX/1520 group E6000H emulator (HS1527KEPH60H; hereinafter referred to as the emulator) to the IC socket for an FP-100M package for the H8SX/1520 group MCU on the user system. Preface i ...

Page 6

Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station .......................................... 3 2.2 Connecting User System Interface Cable to User System................................................. 5 2.2.1 Installing IC Socket.............................................................................................. 5 2.2.2 Soldering IC Socket ............................................................................................. 5 ...

Page 7

... Section 1 Configuration Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100M package IC socket on the user system. Figure 1 shows the configuration of the HS1527ECH61H user system interface cable for the FP-100M package. To emulator station Screws (M2 mm) with flat washers Figure 1 HS1527ECH61H User System Interface Cable ...

Page 8

... Table 1 lists the HS1527ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS1527ECH61H Components No. Component 1 Cable body 2 Cable head 3 IC socket 4 Socket cover 5 Screws (M2 mm) 6 Screws (M2 mm) 7 Documentation 2 Quantity Remarks 1 Cable 1 1 For the FP-100M package 1 For installing an FP-100M packaged MCU ...

Page 9

Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will ...

Page 10

After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket (figure 2). E6000H RENESAS HS1527KEPH60H emulator station Figure 2 Example of the HS1527KEPH60H Emulator Station 4 ...

Page 11

Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 ...

Page 12

Inserting Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-100M package on the user system with pin 1 on the user system interface cable head, and insert the ...

Page 13

Fasten the user system interface cable head to the IC socket for an FP-100M package on the user system with the four screws (M2.6 tightened a little at a time, alternating between screws on opposing corners. Take special care, such ...

Page 14

Fastening Cable Body Connect the cable body to the cable head. Cable body User system 8 Remove jig Cable head Figure 4 Fastening Cable Body Removing Push the remove jigs ...

Page 15

Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-100M package (IC149-100-054-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that ...

Page 16

Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10 29.5 17.0 63.50 Unit: mm Tolerance: ±0.5 mm ...

Page 17

Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head User system Figure 7 Resulting Dimensions after Connecting User ...

Page 18

Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0785 N•m or less. If ...

Page 19

User system Figure 8 Installing MCU to User System Screws (M2 mm) with flat washers Socket cover MCU Pin 1 IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) 13 ...

Page 20

Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE). 2. Verify the user system interface cable connections by checking the pin states with the CHECK command (emulator ...

Page 21

Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. This user system interface cable is ...

Page 22

A level-shift circuit with AVcc0 and AVcc1 is mounted on the user system interface cable, as shown in figure 12. At shipment, the jumper pin is inserted in the side of pins 1 and 2 of the P4 short ...

Page 23

Renesas Microcomputer Development Environment System User's Manual H8SX/1520 Group FP-100M User System Interface Cable Publication Date: Rev.1.00, January 12, 2005 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., ...

Page 24

RENESAS SALES OFFICES Refer to "http://www.renesas.com/en/network" for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.S.A Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501 Renesas Technology Europe Limited Dukes Meadow, Millboard Road, ...

Page 25

... User System Interface Cable HS1527ECH61H User’s Manual 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan H8SX/1520 Group FP-100M REJ10B0173-0100 ...