... H8/36912, H8/36902 Group FP-32D User System Interface 8 Cable for E6000 Emulator HS36902ECF61H HS36902ECF61HE User’s Manual Renesas Microcomputer Development Environment System H8 Family / H8/300H Tiny Series www.renesas-electoronics.com Rev.1.00 2004.06 ...
Page 4
...
Page 5
Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead ...
Page 6
... Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products. • User system interface cable (HS36902ECF61H) The user system or a host computer is not included in this definition. Purpose of the User System Interface Cable: This user system interface cable is for connecting the emulator station and user system ...
Page 7
LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in ...
Page 8
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and ...
Page 9
READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL ...
Page 10
Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST not ...
Page 11
... Thank you for purchasing this user system interface cable (HS36902ECF61H) for the Renesas’ original microcomputer H8/36912, H8/36902 group. The HS36902ECF61H is a user system interface cable that connects an H8/36912, H8/36902 group E6000 emulator (HS3664EPI61H or HS3664EPI62H; hereinafter referred to as the emulator) to the IC socket for an FP-32D package for the H8/36912, H8/36902 group MCU on the user system ...
Page 12
Section 1 Configuration.....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station ......................................... 3 2.2 Connecting User System Interface Cable to User System ................................................ 5 2.2.1 Installing IC Socket ............................................................................................. 6 2.2.2 Inserting Cable Head ...
Page 13
... Use an NSPACK032YU socket (manufactured by Tokyo Eletech Corporation) for the FP-32D package IC socket on the user system. Figure 1 shows the configuration of the HS36902ECF61H user system interface cable for the FP-32D package. To emulator station Screws ( mm) Figure 1 HS36902ECF61H User System Interface Cable Section 1 Configuration CAUTION ...
Page 14
... Table 1 lists the HS36902ECF61H components. Please make sure you have all of these components when unpacking. Table 1 HS36902ECF61H Components No. Component 1 Cable body 2 Cable head 3 IC socket 4 Socket cover 5 Screws ( mm) 6 Screws ( mm) 7 CTS screws ( mm) 8 Screwdriver 9 Documentation 2 Quantity Remarks 1 Coaxial cable 1 1 For the FP-32D package ...
Page 15
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will ...
Page 16
Figure 2 Connecting User System Interface Cable to Emulator Station 4 Emulator station Cable body connector CTS screws ( mm) User system interface cable ...
Page 17
Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 ...
Page 18
Installing IC Socket 1. After confirming the location of pin 1 on the IC socket, apply epoxy resin adhesive to the end of the two projections at the bottom of the IC socket, and fasten it to the user ...
Page 19
Fastening Cable Head 1. Use the screwdriver provided for tightening screws. 2. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw ...
Page 20
Fasten the user system interface cable head to the IC socket for an FP-32D package on the user system with the two screws (M2 time, alternating between screws on opposing corners. Take special care, such as manually securing the IC ...
Page 21
Fastening Cable Body Connect the cable body to the cable head. Cable body User system Remove jig Cable head Figure 5 Fastening Cable Body Removing Push the two remove jigs. 9 ...
Page 22
Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-32D package (NSPACK032YU: manufactured by Tokyo Eletech Corporation). Note that the ...
Page 23
Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Figure 7 Dimensions for User System Interface Cable Head 30.0 18.0 66.0 Unit: mm Tolerance: ±0 ...
Page 24
Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. Cable head User system Figure 8 Resulting Dimensions after Connecting User ...
Page 25
Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws. 3. The tightening torque must be 0.098 N•m or less. If the applied torque ...
Page 26
User system Figure 9 Installing MCU to User System 14 Screws ( mm) Socket cover Pin 1 MCU IC socket (NSPACK032YU manufactured by Tokyo Eletech Corporation) ...
Page 27
Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8/3664 E6000 Emulator User’s Manual (HS3664EPI61HE-U2 or HS3664EPI62HE-U2). 2. Verify the user system interface cable connections by accessing ports and checking the bus states ...
Page 28
Figure 10 shows the system clock oscillator on the user system interface cable and the subclock input specifications MΩ HCU04 To E6000 emulator HCU04 R2 270 Ω OSC1 OSC2 System clock oscillator Figure 10 System Clock Oscillator and ...
Page 29
Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount ...
Page 30
The P1 short connector is used for testing. Do not remove the inserted jumper pin Figure 12 P1 Short Connector ...
Page 31
SW1 and SW2 are used to switch OSC2 or PC1 and OSC1 or PC0. Turn SW1 and SW2 to the OSC1 and OSC2 sides, respectively, when they are used as OSC1 and OSC2. Turn SW1 and SW2 to the ...
Page 32
H8/36912, H8/36902 Group FP-32D User System Interface Cable for E6000 Emulator User's Manual Publication Date: Rev.1.00, Jun 16, 2004 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd. ...