HS3887ECN61H Renesas Electronics America, HS3887ECN61H Datasheet

no-image

HS3887ECN61H

Manufacturer Part Number
HS3887ECN61H
Description
DEV EMULATOR PCB ADAPTOR
Manufacturer
Renesas Electronics America
Datasheet

Specifications of HS3887ECN61H

Accessory Type
User Interface Cable
For Use With/related Products
H8/3827, H8/3847
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
To our customers,
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Renesas Electronics website:
Old Company Name in Catalogs and Other Documents
http://www.renesas.com
April 1
Renesas Electronics Corporation
st
, 2010

Related parts for HS3887ECN61H

HS3887ECN61H Summary of contents

Page 1

To our customers, Old Company Name in Catalogs and Other Documents st On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the ...

Page 2

All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm ...

Page 3

...

Page 4

... H8/3887 Series TQFP-100G User System Interface Cable (HS3887ECN61H) for E6000 Emulator User’s Manual ...

Page 5

...

Page 6

... Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Hitachi, Ltd. excluding all subsidiary products. User system interface cable (HS3887ECN61H) The user system or a host computer is not included in this definition. Purpose of the User System Interface Cable: This user system interface cable is for connecting the emulator station and user system ...

Page 7

LIMITED WARRANTY Hitachi warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Hitachi will repair or replace any user system interface cables determined to be defective in ...

Page 8

State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and ...

Page 9

READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL ...

Page 10

WARNING Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST ...

Page 11

Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Hitachi bears no responsibility for problems that may arise with ...

Page 12

...

Page 13

... Thank you for purchasing this user system interface cable (HS3887ECN61H) for the Hitachi’s original microcomputer H8/3887 series. The HS3887ECN61H is a user system interface cable that connects an H8/3864 series, H8/3887 series E6000 emulator (HS3880EPI60H; hereinafter referred to as the emulator) to the IC socket for a TQFP-100G package (package code: TFP-100G) for the H8/3887 series MCU on the user system ...

Page 14

Section 1 Configuration ....................................................................................1 Section 2 Connection Procedures ......................................................................4 2.1 Connecting User System Interface Cable to Emulator Station ..........................................4 2.2 Connecting User System Interface Cable to User System .................................................5 2.2.1 Installing IC Socket ..............................................................................................6 2.2.2 Soldering IC Socket..............................................................................................7 2.2.3 Inserting ...

Page 15

... Section 1 Configuration Use an NQPACK100SE socket (manufactured by Tokyo Eletech Coporation) for the TFP-100G package IC socket on the user system. Figure 1 shows the configuration of the HS3887ECN61H user system interface cable for the TFP-100G package. CAUTION 1 ...

Page 16

... Figure 1 HS3887ECN61H User System Interface Cable 2 ...

Page 17

... Table 1 lists the HS3887ECN61H components. Please make sure you have all of these components when unpacking. Table 1 HS3887ECN61H Components No. Component 1 Cable body 2 Cable head 3 IC socket 4 Socket cover 5 Screws ( mm) 6 Screws ( mm) 7 Guide pins ( 1 mm) 8 Screwdriver 9 Documentation Quantity Remarks 1 Includes flat cable ...

Page 18

Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will ...

Page 19

Emulator station Figure 2 Connecting User System Interface Cable to Emulator Station 2.2 Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to ...

Page 20

Installing IC Socket After checking the location of pin 1 on the IC socket fasten it to the user system before soldering. After confirming the location of pin 1 on the IC socket, apply epoxy resin adhesive to the ...

Page 21

Soldering IC Socket After fastening, solder the IC socket for a TFP-100G package to the user system. Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets. (Use slightly ...

Page 22

Fastening Cable Head 1. Use the screwdriver provided for tightening screws. 2. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw ...

Page 23

Fasten the user system interface cable head to the IC socket for a TFP-100G package on the user system with the four screws (M2 x alternating between screws on opposing corners. Take special care, such as manually securing the IC ...

Page 24

Fastening Cable Body Connect the cable body to the cable head. Cable body User system Figure 5 Fastening Cable Body 10 Push the unfastening jig Unfastening jig Cable head Removing ...

Page 25

Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for a TFP-100G package (NQPACK100SE: manufactured by Tokyo Eletech Coporation). Note that the ...

Page 26

Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Figure 7 Dimensions for User System Interface Cable Head 12 ...

Page 27

Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. Figure 8 Resulting Dimensions after Connecting User System Interface Cable 13 ...

Page 28

Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws. 3. The tightening torque must be 0.054 N•m or less. If the applied torque ...

Page 29

Figure 9 Installing MCU to User System 15 ...

Page 30

Section 4 Verifying Operation 1. When using the H8/3864 series and H8/3887 series E6000 emulator (HS3880EPI60H), turn on the emulator according to the procedures described in the H8/3864 series and H8/3887 series E6000 Emulator User's Manual (HS3880EPI60HE). 2. Verify the ...

Page 31

Figure 10 shows the system clock oscillator on the user system interface cable and the subclock input specifications HCU04 To E6000 emulator HCU04 R2 270 OSC1 OSC2 System clock oscillator Figure 10 System Clock Oscillator and Subclock ...

Page 32

Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount ...

Page 33

The P1 short connector is used for testing. Do not remove the inserted jumper pin Figure 12 P1 Short Connector 19 ...

Related keywords