IS-DEV KIT-5C NKK Switches, IS-DEV KIT-5C Datasheet - Page 15

SMARTSWITCH DEVELOPMENT KIT 5C

IS-DEV KIT-5C

Manufacturer Part Number
IS-DEV KIT-5C
Description
SMARTSWITCH DEVELOPMENT KIT 5C
Manufacturer
NKK Switches
Series
SmartSwitch™r
Datasheet

Specifications of IS-DEV KIT-5C

Main Purpose
Switches with Programmable Display
Utilized Ic / Part
IS15SBFP4RGB
Primary Attributes
2 LCD Switches, PC Board with Flash Memory
Secondary Attributes
Power and Programming Connections
Description/function
SMARTSWITCH Development Kit
For Use With
360-2431 - SERIAL CBL RJ11-DB9 FOR DEV KIT360-2430 - POWER SUPPLY 240VAC FOR DEV KIT360-2429 - POWER SUPPLY 120VAC FOR DEV KIT
Lead Free Status / RoHS Status
Not applicable / Not applicable
Embedded
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
Smart Switch - RGB
Other names
360-2327
IS-DEV KIT-4
7850 East Gelding Drive • Scottsdale, AZ 85260-3420
Command to download FLAG B
[FLAG B] is one byte. See table below.
This command is for duration of the session. It can become permanent by “Command to write the setup
values to the EPROM”.
Command to set timers for LED up/ LED down
[Timer1] is one byte from 01H to FFH. 00H is not acceptable. Default (09H)
[Timer2] is one byte from 00H to FFH. 00H =256. Default (09H)
This command does not go to effect until it becomes permanent. It can become permanent by “Command to
write the setup values to the EPROM”.
Command to download power up Addresses
[Address for Switch 1] is one byte from 01H to FFH. 00H is not acceptable. Default (01H)
[Address for Switch 1] is one byte from 01H to FFH. 00H is not acceptable. Default (02H)
This command does not go to effect until it becomes permanent. It can become permanent by “Command to
IS-Dev Kit-5 and IS-Dev Kit-6 Users Manual A.doc
This command sets Flag B.
This command sets the timers that determine the time “DOWN LED” and “UP LED” are displayed upon
power up. Every time the switches are pressed the timers get reset.
This command sets the addresses for switch 1 and switch 2 upon power up or reset.
write the setup values to the EPROM”.
B0
B1
B2
B3
B4
B5
B6
B7
Bit
command format:
transmit format:
Flag Byte B Default Value=01H
command format:
transmit format:
command format:
transmit format:
Enable
Value
Toll Free 1.877.2BUYNKK (877.228.9655) • Phone 480.991.0942 • Fax 480.998.1435
1
0
0
0
0
0
0
0
BEEPER
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
(xxH) (xxH) (xxH)
(xxH) (xxH) (xxH) (xxAH)
(xxH) (xxH) (xxH)
26H
26H
26H
IS-Dev Kit-5 and IS-Dev Kit-6 Users
www.nkkswitches.com • Email engineering@nkkswitches.com
51H
51H
51H
Flag
5DH [Timer1] [Timer2]
5CH [FLAG B]
5EH [Address for Switch 1] [Address for Switch 2]
Manual
(xxAH)
(xxAH)
Beep for switch press
(xxAH)
Controller action when flag is set
(xxAH)
Page 15 of 24