EVB9512 SMSC, EVB9512 Datasheet - Page 39

no-image

EVB9512

Manufacturer Part Number
EVB9512
Description
EVALUATION BOARD FOR LAN9512
Manufacturer
SMSC
Datasheets

Specifications of EVB9512

Main Purpose
Interface, Ethernet Controller (PHY and MAC)
Embedded
No
Utilized Ic / Part
LAN9512
Primary Attributes
Single Chip Hi-Speed USB to 10/100 Ethernet
Secondary Attributes
Full Duplex and HP Auto-MDIX Support, 10BASE-T and 100BASE-TX
Other names
638-1093
EVB9512LC
USB 2.0 Hi-Speed Hub Controller
Datasheet
SMSC USB251x
8.2.1.8
NUMBER
NUMBER
BIT
BIT
2:1
5:4
2:0
0
7
6
3
Register 07h: Configuration Data Byte 2
CURRENT_SNS
COMPOUND
PORT_PWR
OC_TIMER
BIT NAME
BIT NAME
DYNAMIC
Reserved
Reserved
Over-Current Sense: Selects current sensing on a port-by-port basis, all
ports ganged, or none (only for bus-powered hubs). The ability to support
current sensing on a port or ganged basis is hardware implementation
dependent.
‘00’ = Ganged sensing (all ports together)
‘01’ = Individual (port-by-port)
‘1x’ = Over-current sensing not supported (must only be used with bus-
powered configurations!)
Port Power Switching: Enables power switching on all ports simultaneously
(ganged), or port power is individually switched on and off on a port- by-port
basis (individual). The ability to support power enabling on a port or ganged
basis is hardware implementation dependent.
‘0’ = Ganged switching (all ports together)
‘1’ = Individual port-by-port switching
Dynamic Power Enable: Controls the ability of the hub to automatically
change from self-powered operation to bus-powered operation if the local
power source is removed or is unavailable (and from bus-powered to self-
powered if the local power source is restored).
When dynamic power switching is enabled, the hub detects the availability
of a local power source by monitoring the external LOCAL_PWR pin. If the
hub detects a change in power source availability, the hub immediately
disconnects and removes power from all downstream devices and
disconnects the upstream port. The hub will then re-attach to the upstream
port as either a bus-powered hub (if local-power is unavailable) or a self-
powered hub (if local power is available).
‘0’ = No dynamic auto-switching
‘1’ = Dynamic auto-switching capable
Reserved
OverCurrent Timer: Over-current Timer delay.
‘00’ = 0.1 ms
‘01’ = 4.0 ms
‘10’ = 8.0 ms
‘11’ = 16.0 ms
Compound Device: Allows OEM to indicate that the hub is part of a
compound (see the USB specification for definition) device. The applicable
port(s) must also be defined as having a "Non-Removable Device".
Note:
‘0’ = No
‘1’ = Yes, The hub is part of a compound device
Reserved
When configured via strapping options, declaring a port as non-
removable automatically causes the hub controller to report that it
is part of a compound device.