MAX5661EVCMAXQU+ Maxim Integrated Products, MAX5661EVCMAXQU+ Datasheet - Page 24

no-image

MAX5661EVCMAXQU+

Manufacturer Part Number
MAX5661EVCMAXQU+
Description
EVALUATION SYSTEM FOR MAX56611
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of MAX5661EVCMAXQU+

Number Of Dac's
1
Number Of Bits
16
Outputs And Type
2, Single Ended
Data Interface
Serial
Dac Type
Current/Voltage
Voltage Supply Source
Single
Operating Temperature
-40°C ~ 105°C
Utilized Ic / Part
MAX5661
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Single 16-Bit DAC with Current and Voltage
Outputs for Industrial Analog Output Modules
Table 4. Control Register (Read/Write)
24
CLRFLAGEN
OUTI4/0EN
BIT NAME
CLRMODE
I4TO20BIT
FAULTEN
CLEARST
OUTVON
OUTION
FAULTV
CLREN
FAULTI
RCLR
_______________________________________________________________________________________
B/U
X
D1, D0
DATA
D15
D14
D13
D12
D11
D10
BIT
D9
D8
D7
D6
D5
D4
D3
D2
RESET
STATE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
DAC OUTV output enable bit. Set to 1 to enable the OUTV output.
DAC OUTI output enable bit. Set to 1 to enable the OUTI output.
Reserved. Always set to 0.
Voltage-output unipolar/bipolar mode select bit. Set to 0 (default power-up state) to select the
bipolar output range (±10.48V). Set to 1 to select the unipolar output range (0 to +10.48V).
OUTI4/0 enable bit. Set to 0 (default power-up state) to enable the OUTI4/0 hardware input. Set
to 1 to disable the OUTI4/0 hardware input, thereby controlling the current-output range
through software commands.
OUTI current range bit. Set to 0 to set the OUTI current range from 0 to 20mA. Set to 1 to set
the OUTI current range from 4–20mA.
Clear enable bit. Set to 0 to enable the external CLR input. Set to 1 to disable the external CLR
input.
Clear mode bit. Set to 1 and drive the external CLR input low to force the DAC output to the
value stored in the clear register. Set to 0 and drive the external CLR input low to force the DAC
output to 0V in voltage mode or 0mA/4mA depending on output-current mode.
Remain in clear bit. Set to 1 to remain in the clear state. The RCLR bit determines the steps
required to exit the clear state. See the CLR Input section.
Fault output enable. Set to 1 to enable the FAULT output functionality. Set to 0 to disable the
FAULT output functionality. In single supply mode, set to 0 to disable the FAULT pin function.
C l ear fl ag enab l e. S et to 1 to enab l e the FAU LT outp ut to r ep or t w hen the d evi ce i s i n the cl ear state.
Output voltage fault bit (read only). The FAULTV bit is set to 1 when FAULT triggers due to an
OUTV short-circuit condition. The FAULTV bit is a don’t-care bit for control-register write
commands. In single supply mode, FAULTV = 1 must be ignored.
Output-current fault bit (read only). The FAULTI bit is set to 1 when FAULT triggers due to an
OUTI open-circuit condition. The FAULTI bit is a don’t-care bit for the control register write
commands. In single supply mode, monitor the FAULTI bit for any FAULTI condition.
C l ear state b i t ( r ead onl y) . The C LE ARS T b i t i s set to 1 w hen CLR i s l ow and C LRE N = 0. The C LRS T
b i t i s a d on’ t- car e b i t for contr ol r eg i ster w r i te com m and s.
Not used.
FUNCTION

Related parts for MAX5661EVCMAXQU+