AS5043 AB austriamicrosystems, AS5043 AB Datasheet - Page 18

no-image

AS5043 AB

Manufacturer Part Number
AS5043 AB
Description
BOARD ADAPTER AS5043
Manufacturer
austriamicrosystems
Datasheets

Specifications of AS5043 AB

Sensor Type
Magnetic, Rotary Position
Sensing Range
360°
Interface
Serial
Voltage - Supply
9V
Embedded
No
Utilized Ic / Part
AS5043
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Sensitivity
-
AS5043
Data Sheet – Analog Readback Mode
13 Analog Readback Mode
Non-volatile programming (OTP) uses on-chip zener diodes, which become permanently low resistive when subjected to
a specified reverse current.
The quality of the programming process depends on the amount of current that is applied during the programming
process (up to 130mA). This current must be provided by an external voltage source. If this voltage source cannot
provide adequate power, the zener diodes may not be programmed properly.
In order to verify the quality of the programmed bits, an analog level can be read for each zener diode, giving an
indication whether this particular bit was properly programmed or not.
To put the AS5043 in Analog Readback Mode, a digital sequence must be applied to pins CSn, PROG and CLK as
shown in Figure 15. The digital level for this pin depends on the supply configuration (3.3V or 5V; see section 1, page 5).
The second rising edge on CSn (OutpEN) changes pin PROG to a digital output and the log. high signal at pin PROG
must be removed to avoid collision of outputs (grey area in Figure 15).
The following falling slope of CSn changes pin PROG to an analog output, providing a reference voltage V
saved as a reference for the calculation of the subsequent programmed and unprogrammed OTP bits.
Following this step, each rising slope of CLK outputs one bit of data in the reverse order as during programming.
(see Figure 15: Output Range OR0 and -1 , ClampMdEn, RefExtEn, FB_IntEn, Z0…Z9, ccw)
During analog readback, the capacitor at pin PROG (see Figure 12) should be removed to allow a fast readout rate.
The measured analog voltage for each bit must be subtracted from the previously measured V
gives an indication on the quality of the programmed bit: a reading of <100mV indicates a properly programmed bit and a
reading of >1V indicates a properly unprogrammed bit.
A reading between 100mV and 1V indicates a faulty bit, which may result in an undefined digital value, when the OTP is
read at power-up.
Following the 16
Figure 15: Analog OTP Register Read
www.austriamicrosystems.com
P R O G
C S n
C L K
P ro g E N
t
th
L oa d P ro g
clock (after reading bit “ccw”), the chip must be reset by disconnecting the power supply.
O u tpE N
In te rn al
te st bit
dig it al
P rog ch an g es t o O u tp u t
V
re f
O R 0
1
O R 1
C la m p
M d E N
C L K
Revision 1.80
A n a log R e a d b a ck D ata a t P R O G
R ef E xt
E N
A re ad
V
u n p rog ram m e d
V
p ro gra m m ed
Z 5
Z 6
Z 7
Z 8
Z 9
ref
, and the resulting value
1 6
c cw
P o w e r-o n -
R e s e t;
c yc le su p ply
ref
, that must be
18 – 36