AS5043 AB austriamicrosystems, AS5043 AB Datasheet - Page 26

no-image

AS5043 AB

Manufacturer Part Number
AS5043 AB
Description
BOARD ADAPTER AS5043
Manufacturer
austriamicrosystems
Datasheets

Specifications of AS5043 AB

Sensor Type
Magnetic, Rotary Position
Sensing Range
360°
Interface
Serial
Voltage - Supply
9V
Embedded
No
Utilized Ic / Part
AS5043
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Sensitivity
-
AS5043
Data Sheet – Angular Output Tolerances
In practice, there is no upper speed limit. The only restriction is that there will be fewer samples per revolution as the
speed increases.
Regardless of the rotational speed, the absolute angular value is always sampled at the highest resolution.
Table 6: Speed Performance
18.5 Output Delays
The propagation delay is the delay between the time that the sample is taken until it is available as angular data. This
delay is 96µs in fast mode (pin Mode = high) and 384µs in slow mode (pin Mode = low or open).
The analog output produces no further delay, the output voltage will be updated as soon as it is available. Using the SSI
interface for data transmission, an additional delay must be considered, caused by the asynchronous sampling
(0….1/f
18.5.1 Angular Error Caused by Propagation Delay
A rotating magnet will cause an angular error caused by the propagation delay.
This error increases linearly with speed:
where
Note: since the propagation delay is known, it can be automatically compensated by the control unit processing the data
from the AS5043.
18.6 Internal Timing Tolerance
The AS5043 does not require an external ceramic resonator or quartz. All internal clock timings for the AS5043 are
generated by an on-chip RC oscillator. This oscillator is factory trimmed to ±5% accuracy at room temperature (±10%
over full temperature range). This tolerance influences the ADC sampling rate:
18.6.1 Absolute Output; SSI Interface
A new angular value is updated every
96µs +/- 5% (Mode = 1) or
384µs +/- 5% (Mode = 0 or open)
www.austriamicrosystems.com
n
e
Fast Mode
(Pin Mode = 1)
610rpm = 1024 samples / turn
1220rpm = 512 samples / turn
2441rpm = 256 samples / turn
etc…
sampling
=
rpm
sample
(deg)
e
rpm = rotating speed [rpm]
prop.delay = propagation delay [seconds]
60
384
sampling
) and the time it takes the external control unit to read and process the angular data from the AS5043.
μ
=
s
= angular error [°]
for slow mode
6
rpm
pr
.
delay
Slow Mode
(Pin Mode = 0 or open)
610rpm = 256 samples / turn
1220rpm = 128 samples / turn
2441rpm = 64 samples / turn
etc…
Revision 1.80
26 – 36