HS0005KCU11H Renesas Electronics America, HS0005KCU11H Datasheet - Page 199

EMULATOR E10A-USB H8S(X),SH2(A)

HS0005KCU11H

Manufacturer Part Number
HS0005KCU11H
Description
EMULATOR E10A-USB H8S(X),SH2(A)
Manufacturer
Renesas Electronics America
Type
In Circuit Debuggerr
Datasheet

Specifications of HS0005KCU11H

Contents
E10A-LITE, Cable and CD-ROM
Core Architecture
H8S, H8SX And SH2
Kit Contents
E10A-LITE, Cable And CD-ROM
Features
H-UDI Interface, 14-Way Cable
Tool / Board Applications
General Purpose MCU, MPU, DSP, DSC
Core Sub-architecture
H8S, H8SX, SH2
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
H8S, H8SX, SH-2, SH-2A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
9. [I/O] Window
10. Note on [Register] Window Operation During Program Execution
11. Break Functions
12. Number of BREAKPOINT and [Stop At] Settings in the [Run...] Menu
13. Note on RUN-TIME Display
14. Note on Displaying Timeout error
⎯ Display and modification
The register value cannot be changed in the [Register] window during program execution. Even
if the changed value is displayed, the register contents are not changed actually.
When the PC breakpoint is set in the flash memory area, the program is written to the flash
memory each time the user program is executed. At this time, note that the number of
rewritable times will be decreased.
⎯ BREAKPOINT cancellation
The maximum number of BREAKPOINTs and [Stop At] settings allowed in the [Run...] menu
is 255. Therefore, when 255 BREAKPOINTs are set, specification by [Stop At] in the [Run...]
menu becomes invalid. Use the BREAKPOINTs and [Stop At] in the [Run...] menu with 255
or less total settings.
The execution time of the user program displayed in the [Status] window is not a correct value
since the timer in the host computer has been used.
If Timeout error is displayed, the emulator cannot communicate with the target
microcomputer. Turn off the emulator and the user system and connect the emulator again by
using the High-performance Embedded Workshop.
Do not change values in the [I/O Registers] window because the emulator uses the address
break controller.
Note that the emulator does not support the display of the invalid module or bit information
in the [I/O] window.
When the contents of the BREAKPOINT address are modified during user program
execution, the following message is displayed when the user program stops.
stopped has failed. This is because the data at the address has been changed, or writing or
reading was not successful. So the original data has not been written back to the address.
Address = H′xxxx
Checking of data at the address of the breakpoint where the user program execution
Appendix D Notes on High-performance Embedded Workshop
Rev. 12.00 Aug. 28, 2009 Page 179 of 188
REJ10J1140-1200

Related parts for HS0005KCU11H