TOOLSTICK530MPP Silicon Laboratories Inc, TOOLSTICK530MPP Datasheet - Page 5

ADAPTER PROG TOOLSTICK F530MPP

TOOLSTICK530MPP

Manufacturer Part Number
TOOLSTICK530MPP
Description
ADAPTER PROG TOOLSTICK F530MPP
Manufacturer
Silicon Laboratories Inc
Series
ToolStickr
Type
Microcontroller Programmerr
Datasheet

Specifications of TOOLSTICK530MPP

Contents
2 Boards and USB Connecting Cable
Processor To Be Evaluated
C8051F53xA-IM
Interface Type
USB
Operating Supply Voltage
2.7 V to 3.6 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051F530/531/533/534/536/537-IM
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1456
Step 3. Insert the MCU into the socket
Note: The Programming Adapter has a diagram of the MCU that shows the proper orientation of the MCU in the socket. The
The procedure for inserting the device into the socket depends on the type of socket (Clam-Shell, Top-Loader, or
ZIF).
Inserting a device into a Clam-Shell socket
A. Ensure that the ToolStick Base Adapter and the daughter card are on a level surface.
B. Press the latch to open the socket.
C. Using the tweezers, carefully insert the device into the socket in the same orientation that is shown in the orientation
D. Slowly close the socket so that the device does not move during the process.
diagram on the daughter card.
circle in the diagram corresponds to the circle on the top-side of the package. Please check the orientation of the device
before inserting into the socket. Inserting the device incorrectly into the socket could damage the device.
ToolSt ick Programming Adapter
Figure 7. Socket Orientation
Figure 8. Clam-Shell Socket