HL1-HP-AC12V Panasonic Electric Works, HL1-HP-AC12V Datasheet - Page 6

no-image

HL1-HP-AC12V

Manufacturer Part Number
HL1-HP-AC12V
Description
RELAY POWER 15A 12VAC PCB
Manufacturer
Panasonic Electric Works
Series
HLr
Datasheet

Specifications of HL1-HP-AC12V

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
15A
Switching Voltage
125VAC
Coil Type
Standard
Coil Current
100mA
Coil Voltage
12VAC
Turn On Voltage (max)
9.6 VAC
Turn Off Voltage (min)
3.6 VAC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
15A @ 125VAC
Control On Voltage (max)
9.6 VAC
Control Off Voltage (min)
3.6 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
HL
3. TM type
1 Form C
2 Form C
For Cautions for Use, see Relay Technical Information.
7
7
3
1
3
5
20.6
.811
.142
.142
20.6
.811
3.6
3.6
6
4
2
2
6
8
8
34.4
1.354
34.4
1.354
3.95
.156
4.6
.181
6
.236
7.15
.281
6.35
.250
6.35
.250
External dimensions
External dimensions
3.7
.146
4.7
.185
6
.236
7.3
.287
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Compatible with tab terminal
#187 series receptacle.
37.6
1.480
Compatible with tab terminal
#187 series receptacle.
37.6
1.480
.079
.079
2
2
General tolerance: ±0.3
General tolerance: ±0.3
.020
.020
0.5
0.5
1.693
1.693
43
43
±.012
±.012
1.2
.047
1.2
.047
Tolerance: ±0.1
Notes: 1. If connecting to #187 series tab terminals, use AMP Faston
Tolerance: ±0.1
Notes: 1. If connecting to #187 series tab terminals, use AMP Faston
Chassis (Panel) cutout
Chassis (Panel) cutout
2. In mounting, use M3 screws and M3 washers.
3. When mounting TM types, use washers to prevent damage
4. When tightening fixing screws, the optimum torque range
2. In mounting, use M3 screws and M3 washers.
3. When mounting TM types, use washers to prevent damage
4. When tightening fixing screws, the optimum torque range
#187 series or #187 tab terminals conforming to UL or CSA
inch-standard dimensions.
or distortion to the polycarbonate cover.
should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm). Moreover, use
washers to prevent loosening.
#187 series or #187 tab terminals conforming to UL or CSA
inch-standard dimensions.
or distortion to the polycarbonate cover.
should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm). Moreover, use
washers to prevent loosening.
1.470
1.470
37.6
37.6
Schematic (Bottom view)
Schematic (Bottom view)
±.004
±.004
2-3.2 to 3.5 dia. hole
2-.126 to .138 dia.
2-3.2 to 3.5 dia. hole
2-.126 to .138 dia.
Standard type
Standard type
7
7
3
1
3
5
2
4
6
2
6
Chassis (Panel) cutout
Chassis (Panel) cutout
8
in tandem mounting
8
in tandem mounting
1.470
1.470
37.6
37.6
.827
.827
21
21
.906
.079
.906
.079
23
23
2
2
.827
.827
21
21

Related parts for HL1-HP-AC12V