G5V-1-DC6 Omron, G5V-1-DC6 Datasheet - Page 3

RELAY MINI PCB SPDT 1A 6VDC

G5V-1-DC6

Manufacturer Part Number
G5V-1-DC6
Description
RELAY MINI PCB SPDT 1A 6VDC
Manufacturer
Omron
Series
G5V-1r
Datasheets

Specifications of G5V-1-DC6

Coil Type
Standard
Coil Current
25mA
Relay Type
General Purpose
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
1A @ 24VDC
Coil Voltage
6VDC
Control On Voltage (max)
4.8 VDC
Control Off Voltage (min)
0.6 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Form
1 Form C
Power Consumption
150 mW
Maximum Switching Current
2 A
Contact Configuration
SPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
24V
Coil Voltage Vdc Nom
6V
Current, Rating
1 A
Function
Sensitive
Number Of Pins
6
Power, Rating
62.5⁄30 VA⁄W
Standards
UL, CSA, RoHS
Termination
Through Hole
Voltage, Control
6 VDC
Voltage, Rating
125 VAC
High Sensitivity
150 mW Nominal Power Consumption
Small Size
10 mm (H) × 7.5 mm (W) × 12.5 mm (L)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G5V-1-DC6
G5V1DC6
Z2538
■ Characteristic Data
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated. To convert millimeters into inches, multiply by 0.03937.
G5V-1
Precautions
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously
for long periods (without switching) can lead to unstable contacts,
because the heat generated by the coil itself will affect the insulation,
causing a film to develop on the contact surfaces. Be sure to use a
fail-safe circuit design that provides protection against contact failure
or coil burnout.
Maximum Switching Capacity
2. Numbers in parentheses are reference values.
3. Tolerance: ±0.1
4. Orientation marks are indicated as follows:
DC resistive load
Rated Operating voltage (V)
10 max.
(9.9)
3.5
AC
resistive
load
0.5
0.5
0.3
12.5 max.
(12.3)*
Electrical Service Life
5,000
3,000
1,000
700
500
300
100
0.3
70
50
125-VAC
resistive
load
Rated Operating current (A)
7.5 max.
(7.3)*
0.5
* Average value
24-VDC resistive load
Terminal Arrangement/
Internal Connections
(Bottom View)
Relay Handling
When washing the product after soldering the Relay to a PCB, use a
water-based solvent or alcohol-based solvent, and keep the solvent
temperature to less than 40°C. Do not put the Relay in a cold clean-
ing bath immediately after soldering.
1
10
2
9
Note: The maximum coil voltage refers to the maxi-
Low Signal Relay
5
6
Ambient Temperature vs.
Maximum Coil Voltage
Six, 1-dia. holes
mum value in a varying range of operating
power voltage, not a continuous voltage.
(1.07)
Ambient temperature (°C)
Mounting Holes
(Bottom View)
Rated coil voltage
2.54 7.62
10.16+0.1
G5V-1
5.08+0.1
(1.07)
(1.11)
(1.11)
47

Related parts for G5V-1-DC6