G6EU-134P-ST-US-DC12 Omron, G6EU-134P-ST-US-DC12 Datasheet - Page 3

RELAY LOW SIGNAL

G6EU-134P-ST-US-DC12

Manufacturer Part Number
G6EU-134P-ST-US-DC12
Description
RELAY LOW SIGNAL
Manufacturer
Omron
Series
G6Er
Datasheet

Specifications of G6EU-134P-ST-US-DC12

Relay Type
General Purpose
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
2A @ 30VDC
Coil Type
Latching, Single Coil
Coil Current
16.7mA
Coil Voltage
12VDC
Control On Voltage (max)
8.4 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Form
1 Form C
Power Consumption
200 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6EU134PSTUSDC12
Low-sensitivity Dual Coil Latching Type (G6EK-134PL(-ST)-US)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
■ Characteristics
Note: 1. The contact resistance was measured with 1A at 5VDC with a fall-of-potential method.
■ Characteristic Data
3
5
6
9
12
24
Contact resistance (See note 1)
Operate time (set) time (See note 2)
Release time (reset) time (See note 2)
Min. set/reset signal width
Operating frequency
(max.)
Insulation resistance (See note 3)
Dielectric strength
Surge withstand voltage
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
Maximum Switching Capacity
voltage
Rated
(VDC)
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
2. Values in parentheses are typical values unless otherwise stated.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those for checking the dielectric strength
4. The above values are initial values.
DC inductive load
(L/R = 7 ms)
Rated operating voltage (V)
AC inductive load
(cosf = 0.4)
133
79.40
66.60
44.30
33.30
16.70
current
Rated
(mA)
DC resistive load
AC resistive
load
Mechanical
Electrical
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
22.50
63
90
203
360
1,440
Note: The maximum coil voltage refers to the maximum value in a varying range of
resistance
Coil
(Ω)
operating power voltage, not a continuous voltage.
0.02
0.04
0.06
0.12
0.21
0.80
100,000
50,000
10,000
1,000
Armature
3,000
5,000
3,000
500
300
100
50
Electrical Service Life
OFF
50 mΩ max.
5 ms max. (mean value approx. 2.90 ms, 48 VDC type, approx. 2.40 ms)
5 ms max. (mean value approx. 1.30 ms)
Latching type: 15 ms min. (at 23°C)
36,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min. (at 500 VDC)
1,500 VAC, 50/60 Hz for 1 minute between coil contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
1,500 V (10 x160 μs) (conforms to FCC Part 68)
2,500 V (2 x 10 μs) (Telcordia Requirement)
10 to 55 Hz; 5 mm double amplitude
10 to 55 Hz; 3.3 mm double amplitude
1,000 m/s
300 m/s
-40°C to 70°C with no icing
5% to 85% RH
100 million operations min. (at 36,000 operations/hour)
100,000 operations min (0.4A at 125 VAC resistive; 0.2A at 125VAC inductive)
500,000 operations min. (2A at 30 VDC resistive; 1A at 30VDC inductive)
200,000 operations min. (3A at 30 VDC resistive)
See “Characteristic Data”
Approx. 2.7 g
Coil inductance
(ref. value) (H)
Rated operating current (A)
30-VDC inductive load
(L/R = 7 ms)
2
, approx. 30G
2
0.01
0.03
0.04
0.09
0.15
0.58
, approx. 100G
125-VAC inductive load
(cosφ = 0.4)
Armature
30-VDC resistive
load
ON
125-VAC
resistive load
70% max.
Set pick-up
voltage
% of rated voltage
Reset pick-up
70% min.
Low Signal Relay
voltage
Ambient Temperature vs.
Maximum Coil Voltage
G6E-134P-US
Only at 48VDC
Ambient temperature (°C)
170% max.
at 23°C
G6E-134P-US
G6EK-134P-US
G6EU-134P-US
Maximum
voltage
G6E
Approx. 400
consumption
Power
(mW)
91