PM4HA-H-24VSW Panasonic Electric Works, PM4HA-H-24VSW Datasheet - Page 22

no-image

PM4HA-H-24VSW

Manufacturer Part Number
PM4HA-H-24VSW
Description
TIMER RELAY ANALOG 24VAC/DC SCRW
Manufacturer
Panasonic Electric Works
Series
PM4Hr
Datasheet

Specifications of PM4HA-H-24VSW

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.1 Sec ~ 500 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
24VAC/DC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1201
5. Superimposed surge of power
supply (PM4H series common)
For the superimposed surge of power
supply, the standard waveform is taken
as the standard value for surge-proof
voltage.
If external surge occurs exceeding the
specified value, the internal circuit may
break down. In this case, use a surge
absorption element.
applied each five times between the
power pins.
The typical surge absorption elements
include a varistor, a capacitor, and a
diode. If a surge absorption element is
used, use an oscilloscope to see
whether or not the foreign surge exceed-
ing the specified value appears.
The positive and negative voltages are
Operation voltage
12V DC, 24V DC
100 to 240V AC
100 to 120V AC
200 to 240V AC
48 to 125V DC
24V AC/DC
Surge voltage
4,000V
500V
6. Acquisition of CE marking
Please abide by the conditions below
when using in applications that comply
with EN61812-1.
1) Overvoltage category III, pollution
level 2
2) This timer employs a power supply
without a transformer, so the power and
input signal terminals are not insulated.
(PM4H-A only)
(1) When a sensor is connected to the
input circuit, install double insulation on
the sensor side.
(2) In the case of contact input, use dual-
insulated relays, etc.
3) The load connected to the output con-
tact should have basic insulation.
This timer is protected with basic insula-
tion and can be double-insulated to meet
EN/IEC requirements by using basic
insulation on the load.
4) Please use a power supply that is pro-
tected by an overcurrent protection
device which complies with the EN/IEC
standard (example: 250 V 1 A fuse, etc.).
PRECAUTIONS IN USING THE PM4H SERIES
5) You must use a terminal socket or
socket for the installation. Do not touch
the terminals or other parts of the timer
when it is powered. When installing or
un-installing, make sure that no voltage
is being applied to any of the terminals.
6) Do not use this timer as a safety cir-
cuit. For example when using a timer in a
heater circuit, etc., provide a protection
circuit on the machine side.