LD2T06P0 Red Lion Controls, LD2T06P0 Datasheet
LD2T06P0
Specifications of LD2T06P0
Related parts for LD2T06P0
LD2T06P0 Summary of contents
Page 1
... PART X (Length) Y (Height) NUMBER Y LD2T06P0 16 (406.4) 4 (101.6) LD4T06P0 26 (660.4) 7.875 (200) 22 (558.8) 2.25 (57.15) Bulletin No. LDT-F Drawing No. LP0634 Released 09/10 ” ” ...
Page 2
... CONSTRUCTION: Aluminum enclosure, and steel side panels with textured black polyurethane paint for scratch and corrosion resistance protection. Meets NEMA 4X/IP65 specifications. Installation Category II, Pollution Degree 2. 14. WEIGHT: LD2T06P0 - 4.5 lbs (2.04 kg) LD4T06P0 - 10.5 lbs (4.76 kg) DESCRIPTION 2.25" High 6-Digit Red LED Timer/Cycle Counter w/ Relay Output & ...
Page 3
... M ETER 4. Signal or Control cables within an enclosure should be routed as far as possible from contactors, control relays, transformers, and other noisy components extremely high EMI environments, the use of external EMI suppression devices, such as ferrite suppression cores, is effective. Install them on Signal and Control cables as close to the unit as possible. Loop the cable through the core several times or use multiple cores on each cable for additional protection ...
Page 4
WIRING OVERVIEW Electrical connections are made via pluggable terminal blocks located inside the meter. All conductors should conform to the meter's voltage and current ratings. All cabling should conform to appropriate standards of good installation, local codes and regulations. It ...
Page 5
INPUT WIRING The Large Display Timer is equipped with two signal inputs, A and B. These inputs are wired using the six position terminal block (TBB) located inside the unit on the right side. CAUTION: DC common is NOT ...
Page 6
R EVIEWING THE KEY DISPLAY MODE OPERATION PAR Access Programming Mode Select display (Timer or Cycle Counter) SEL RST Reset value(s) per front panel reset setting OPERATING MODE DISPLAY DESIGNATORS “ ” the left of the ...
Page 7
... DAY Provides a 50 msec software debounce for the Timer Inputs (A and B). Select MAXIMUM DISPLAY when using relays or switch contacts as a signal source. DISPLAY RESOLUTION 1 SEC ...
Page 8
TIMER RESET AT POWER-UP The Timer can be programmed to Reset at each meter power-up. USER INPUT FUNCTION DISPLAY MODE DESCRIPTION No Function User Input disabled. See ...
Page 9
MODULE PAR Front Panel Front Panel Display Reset Enable Select FRONT PANEL DISPLAY SELECT ENABLE (SEL The selection allows the key to toggle between the timer and cycle SEL ...
Page 10
MODULE PAR Setpoint Setpoint Setpoint On Assignment Output Action Module 4 is the programming module for the Setpoint Output parameters. Some parameters will not appear depending on the Setpoint Assignment and Setpoint Output Action selected. SETPOINT ...
Page 11
MODULE PAR Baud Rate Data Bit Module 5 is the programming module for the Serial Communications Parameters. These parameters are used to match the serial settings of the meter with those of the host computer or ...
Page 12
Sending Serial Commands and Data When sending commands to the meter, a string containing at least one command character must be constructed. A command string consists of a command character, a value identifier, numerical data (if writing data to the ...
Page 13
Command Response Time The meter can only receive data or transmit data at any one time (half-duplex operation). During RS232 transmissions, the meter ignores commands while transmitting data, but instead uses RXD as a busy signal. When sending commands and ...
Page 14
This page intentionally left blank. 14 ...
Page 15
LD TIMER PROGRAMMING QUICK OVERVIEW 15 ...
Page 16
... The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property ...