F3C-AL14-M1J 0.2M Omron, F3C-AL14-M1J 0.2M Datasheet
F3C-AL14-M1J 0.2M
Specifications of F3C-AL14-M1J 0.2M
F3CAL14M1J02M
Related parts for F3C-AL14-M1J 0.2M
F3C-AL14-M1J 0.2M Summary of contents
Page 1
... Distance setting laser photoelectric sensor F3C-AL Clear red spot ensures easy setting. With its wide setting range 150 to 700 mm, F3C-AL is compat- ible with standard conveyors. In the setting distance of 700 mm, the distance can be set easily with a 1.5x4 mm red spot. 700mm Secure detection of shiny surface Ensures stable detection of a 45-degree shiny surface ...
Page 2
... Cable spec- Shape ifications Straight Standard type cable L type Straight Robot cable type (for vibra- tion resis- tance) L type Red light Model NPN output PNP output F3C-AL14-M1J F3C-AL44-M1J Cable type Model XS2F-D421-D80 XS2F-D421-G80 XS2F-D422-D80 XS2F-D422-G80 con- ductors XS2F-D421-D80 XS2F-D421-G80 XS2F-D422-D80 XS2F-D422-G80-R ...
Page 3
... Adjusting screwdriver, Laser warning label, instruction manual A-250 F3C-AL14-M1J Load supply voltage 30 VDC max., load current 150 mA max. (residual voltage max.) PNP open collector output type, Light-ON/Dark-ON cable connection selectable 2 for each directions 2 for 3 times each and Z directions F3C-AL44-M1J Photoelectric Sensors ...
Page 4
... White paper: reflectivity 90 % Black paper: reflectivity 5 % 2.0 Black paper 1.0 White paper 0 100 200 300 400 500 600 700 Setting distance (mm) F3C-AL Black/White error 10.0 Sensing object White paper: reflectivity 90 % Black paper: reflectivity 5 % 7.5 5.0 2.5 0 150 200 300 400 500 ...
Page 5
... Dark ON Output transistor Load (Relay) PNP output Operating status of Model output transistor Light indicator (red) Light ON Output transistor Load (Relay) F3C-AL44-M1J Light indicator (red) Dark ON Output transistor Load (Relay) Connectors (Sensor I/O connectors) Terminal No. Cable core wire jacket color ...
Page 6
... Handling Instructions F3C radiates a visible-light laser. Do not look into it directly. Use F3C so that the light path of the laser beam is terminated. If there is a mirror-smooth reflector in the light path, confine the beam away from the reflected light path. If F3C must be used with the light path open, avoid placing the light path on the eye level ...
Page 7
... Do not shorten the load with the open collector output. Oth- erwise, damage might be caused. • Run the wiring of F3C separately from the high voltage and power cables. • Avoid wiring them together or running them within the same duct ...