Z8F0213HH005EG Zilog, Z8F0213HH005EG Datasheet - Page 169

IC ENCORE MCU FLASH 2K 20SSOP

Z8F0213HH005EG

Manufacturer Part Number
Z8F0213HH005EG
Description
IC ENCORE MCU FLASH 2K 20SSOP
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheet

Specifications of Z8F0213HH005EG

Core Processor
Z8
Core Size
8-Bit
Speed
5MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, POR, PWM, WDT
Number Of I /o
16
Program Memory Size
2KB (2K x 8)
Program Memory Type
FLASH
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
20-SSOP
For Use With
770-1002 - ISP 4PORT ZILOG Z8 ENCORE! MCU269-4643 - KIT DEV Z8 ENCORE XP 28-PIN269-4630 - DEV KIT FOR Z8 ENCORE 8K/4K269-4629 - KIT DEV Z8 ENCORE XP 28-PIN269-4628 - KIT DEV Z8 ENCORE XP 8-PIN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Other names
269-4044
Z8F0213HH005EG
PS024314-0308
DBG
DBG
Write Program Counter (06H)—The Write Program Counter command writes the data
that follows to the eZ8 CPU’s Program Counter (PC). If the device is not in DEBUG mode
or if the Flash Read Protect Option bit is enabled, the Program Counter (PC) values are
discarded.
DBG
DBG
DBG
Read Program Counter (07H)—The Read Program Counter command reads the value
in the eZ8 CPU’s Program Counter (PC). If the device is not in DEBUG mode or if the
Flash Read Protect Option bit is enabled, this command returns
DBG
DBG
DBG
Write Register (08H)—The Write Register command writes data to the Register File.
Data can be written 1–256 bytes at a time (256 bytes can be written by setting size to 0). If
the device is not in DEBUG mode, the address and data values are discarded. If the Flash
Read Protect Option bit is enabled, only writes to the Flash Control Registers are allowed
and all other register write data values are discarded.
DBG
DBG
DBG
DBG
DBG
Read Register (09H)—The Read Register command reads data from the Register File.
Data can be read 1–256 bytes at a time (256 bytes can be read by setting size to 0). If the
device is not in DEBUG mode or if the Flash Read Protect Option bit is enabled, this com-
mand returns
DBG
DBG
DBG
DBG
DBG
Write Program Memory (0AH)—The Write Program Memory command writes data
to Program Memory. This command is equivalent to the
can be written 1–65536 bytes at a time (65536 bytes can be written by setting size to 0).
The on-chip Flash Controller must be written to and unlocked for the programming oper-
ation to occur. If the Flash Controller is not unlocked, the data is discarded. If the device
05H
OCDCTL[7:0]
06H
ProgramCounter[15:8]
ProgramCounter[7:0]
07H
ProgramCounter[15:8]
ProgramCounter[7:0]
08H
{4’h0,Register Address[11:8]}
Register Address[7:0]
Size[7:0]
1-256 data bytes
09H
{4’h0,Register Address[11:8]
Register Address[7:0]
Size[7:0]
1-256 data bytes
FFH
for all the data values.
Z8 Encore! XP
LDC
and
Product Specification
FFFFH
LDCI
.
®
On-Chip Debugger
instructions. Data
F0823 Series
159

Related parts for Z8F0213HH005EG