HD64F36912GFH Renesas Electronics America, HD64F36912GFH Datasheet - Page 262

IC H8 MCU FLASH 8K 32-QFP

HD64F36912GFH

Manufacturer Part Number
HD64F36912GFH
Description
IC H8 MCU FLASH 8K 32-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F36912GFH

Core Processor
H8/300H
Core Size
16-Bit
Speed
12MHz
Connectivity
I²C, SCI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
18
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
1.5K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
32-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F36912GFH
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 14 Serial Communication Interface 3 (SCI3)
Rev. 3.00 Sep. 14, 2006 Page 232 of 408
REJ09B0105-0300
Yes
No
No
Read OER and FER flags in SSR
Read OER and FER flags in SSR
Figure 14.18 Sample Multiprocessor Serial Reception Flowchart (1)
Read receive data in RDR
Read receive data in RDR
Set MPIE bit in SCR3 to 1
Clear RE bit in SCR3 to 0
Read RDRF flag in SSR
Read RDRF flag in SSR
All data received?
This station’s ID?
Start reception
FER+OER = 1
FER+OER = 1
RDRF = 1
RDRF = 1
<End>
Yes
Yes
Yes
No
No
No
[A]
Yes
No
Yes
[3]
[1]
[2]
Error processing
(Continued on
[4]
next page)
[5]
[1]
[2]
[3]
[4]
[5]
Set the MPIE bit in SCR3 to 1.
Read OER and FER in SSR to check for
errors. Receive error processing is performed
in cases where a receive error occurs.
Read SSR and check that the RDRF flag is
set to 1, then read the receive data in RDR
and compare it with this station’s ID.
If the data is not this station’s ID, set the MPIE
bit to 1 again.
When data is read from RDR, the RDRF flag
is automatically cleared to 0.
Read SSR and check that the RDRF flag is
set to 1, then read the data in RDR.
If a receive error occurs, read the OER and
FER flags in SSR to identify the error. After
performing the appropriate error processing,
ensure that the OER and FER flags are all
cleared to 0.
Reception cannot be resumed if either of
these flags is set to 1.
In the case of a framing error, a break can be
detected by reading the RxD pin value.