COP8CCE9IMT9/NOPB National Semiconductor, COP8CCE9IMT9/NOPB Datasheet - Page 53

IC MCU EEPROM 8BIT 8K 48-TSSOP

COP8CCE9IMT9/NOPB

Manufacturer Part Number
COP8CCE9IMT9/NOPB
Description
IC MCU EEPROM 8BIT 8K 48-TSSOP
Manufacturer
National Semiconductor
Series
COP8™ 8Cr
Datasheet

Specifications of COP8CCE9IMT9/NOPB

Core Processor
COP8
Core Size
8-Bit
Speed
10MHz
Connectivity
Microwire/Plus (SPI), UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
39
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 16x10b
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
48-TSSOP
Data Bus Width
8 bit
Maximum Clock Frequency
10 MHz
Data Ram Size
256 B
On-chip Adc
10 bit, 16 channel
Number Of Programmable I/os
37
Number Of Timers
2
Height
0.9 mm
Interface Type
SPI, USART
Length
12.5 mm
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Width
6.1 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
*COP8CCE9IMT9
*COP8CCE9IMT9/NOPB
COP8CCE9IMT9
15.0 A/D Converter
15.1.1.3 MODE SELECT
This 1-bit field is used to select the mode of operation (single
ended or differential) as shown in the following Table 22.
15.1.1.4 PRESCALER SELECT
This 1-bit field is used to select one of two prescaler clocks
for the A/D Converter. The following Table 23 shows the
various prescaler options. Care must be taken, when select-
ing this bit, to keep the A/D clock frequency within the
specified range.
15.1.1.5 BUSY BIT
The ADBSY bit of the ENAD register is used to control
starting and stopping of the A/D conversion. When ADBSY is
cleared, the prescale logic is disabled and the A/D clock is
turned off, drawing minimal power. Setting the ADBSY bit
starts the A/D clock and initiates a conversion based on the
TABLE 22. A/D Conversion Mode Selection
TABLE 23. A/D Converter Clock Prescale
ADMOD
PSC
0
1
0
1
FIGURE 26. A/D with Single Ended Mux Output Feature Enabled
FIGURE 27. A/D with Differential Mux Output Feature Enabled
(Continued)
Single Ended Mode
MCLK Divide by 16
MCLK Divide by 1
Differential Mode
Clock Select
Mode
53
values currently in the ENAD register. Normal completion of
an A/D conversion clears the ADBSY bit and turns off the A/D
Converter.
If the user wishes to restart a conversion which is already in
progress, this can be accomplished only by writing a zero to
the ADBSY bit to stop the current conversion and then by
writing a one to ADBSY to start a new conversion. This can
be done in two consecutive instructions.
15.1.2 A/D Result Registers
There are two result registers for the A/D converter: the high
8 bits of the result and the low 2-bits of the result. The format
of these registers is shown in Figures 27, 28. Both registers
are read/write registers, but in normal operation, the hard-
ware writes the value into the register when the conversion is
complete and the software reads the value. Both registers
are undefined upon Reset. They hold the previous value until
a new conversion overwrites them. When reading ADRSTL,
bits 5-0 will read as 0.
Bit 7
Bit 7
Bit 9
Bit 1
Bit 8
Bit 0
Bit 7
0
20022529
TABLE 24. ADRSTH
TABLE 25. ADRSTL
20022530
Bit 6
0
Bit 5
0
Bit 4
0
Bit 3
0
www.national.com
Bit 0
Bit 0
Bit 2
0