ZLP32300H4832G Zilog, ZLP32300H4832G Datasheet - Page 40

no-image

ZLP32300H4832G

Manufacturer Part Number
ZLP32300H4832G
Description
IC CRIMZON Z8 MCU OTP 32K 48SSOP
Manufacturer
Zilog
Series
Crimzon™ ZLPr
Datasheets

Specifications of ZLP32300H4832G

Core Processor
Z8
Core Size
8-Bit
Speed
8MHz
Peripherals
Brown-out Detect/Reset, HLVD, POR, WDT
Number Of I /o
32
Program Memory Size
32KB (32K x 8)
Program Memory Type
OTP
Ram Size
237 x 8
Voltage - Supply (vcc/vdd)
2 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
48-SSOP
Data Bus Width
8 bit
Data Ram Size
237 B
Maximum Clock Frequency
8 MHz
Number Of Programmable I/os
32
Number Of Timers
2
Operating Supply Voltage
2 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
For Use With
269-4665 - KIT REMOTE UNVRSL USA 6-FUNCTION
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Connectivity
-
Lead Free Status / Rohs Status
 Details
Other names
269-4510
ZLP32300H4832G
Negative Edge
SCLK
PS020823-0208
Positive Edge
CTR0 D4, D3
Z8 Data Bus
Z8 Data Bus
Note:
Caution:
Select
Clock
When T8 is enabled, the output T8_OUT switches to the initial value (CTR1, D1). If the
initial value (CTR1, D1) is 0, TC8L is loaded; otherwise, TC8H is loaded into the counter.
In SINGLE-PASS mode (CTR0, D6), T8 counts down to 0 and stops, T8_OUT toggles,
the time-out status bit (CTR0, D5) is set, and a time-out interrupt can be generated if it is
enabled (CTR0, D1). In MODULO-N mode, upon reaching terminal count, T8_OUT is
toggled, but no interrupt is generated. From that point, T8 loads a new count (if the
T8_OUT level now is 0), TC8L is loaded; if it is 1, TC8H is loaded. T8 counts down to 0,
toggles T8_OUT, and sets the time-out status bit (CTR0, D5), thereby generating an inter-
rupt if enabled (CTR0, D1). One cycle is thus completed. T8 then loads from TC8H or
TC8L according to the T8_OUT level and repeats the cycle, see
You can modify the values in TC8H or TC8L at any time. The new values take effect
when they are loaded.
The letter
Transition from 0 to
To ensure known operation do not write these registers at the time the values are to be
loaded into the counter/timer. An initial count of 1 is not allowed (a non-function oc-
curs)
.
TC8H
An initial count of 0 causes TC8 to count from 0 to
HI8
Clock
h
denotes hexadecimal values.
Figure 18. 8-Bit Counter/Timer Circuits
FFh
Counter T8
8-Bit
is not a timeout condition.
TC8L
LO8
CTR0 D2
FFh
Product Specification
Figure
to
Crimzon
FEh
Functional Description
18.
.
CTR0 D1
®
ZLP32300
T8_OUT
IRQ4
36