C8051F124 Silicon Laboratories Inc, C8051F124 Datasheet - Page 58

no-image

C8051F124

Manufacturer Part Number
C8051F124
Description
IC 8051 MCU 128K FLASH 100TQFP
Manufacturer
Silicon Laboratories Inc
Series
C8051F12xr
Datasheets

Specifications of C8051F124

Core Processor
8051
Core Size
8-Bit
Speed
50MHz
Connectivity
EBI/EMI, SMBus (2-Wire/I²C), SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Number Of I /o
64
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8.25K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x8b, 8x12b; D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F124
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
C8051F124-GQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
C8051F124-GQR
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
C8051F124-GQR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
C8051F124R
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
C8051F120/1/2/3/4/5/6/7
C8051F130/1/2/3
5.2.2. Tracking Modes
The AD0TM bit in register ADC0CN controls the ADC0 track-and-hold mode. In its default state, the ADC0
input is continuously tracked when a conversion is not in progress. When the AD0TM bit is logic 1, ADC0
operates in low-power track-and-hold mode. In this mode, each conversion is preceded by a tracking
period of 3 SAR clocks (after the start-of-conversion signal). When the CNVSTR0 signal is used to initiate
conversions in low-power tracking mode, ADC0 tracks only when CNVSTR0 is low; conversion begins on
the rising edge of CNVSTR0 (see Figure 5.3). Tracking can also be disabled (shutdown) when the entire
chip is in low power standby or sleep modes. Low-power track-and-hold mode is also useful when AMUX
or PGA settings are frequently changed, to ensure that settling time requirements are met (see
“5.2.3. Settling Time Requirements” on page 59
58
Timer 2, Timer 3 Overflow;
(AD0CM[1:0]=00, 01, 11)
Write '1' to AD0BUSY
(AD0CM[1:0]=10)
SAR Clocks
SAR Clocks
SAR Clocks
ADC0TM=1
ADC0TM=0
ADC0TM=1
ADC0TM=0
CNVSTR0
Figure 5.3. ADC0 Track and Conversion Example Timing
A. ADC Timing for External Trigger Source
B. ADC Timing for Internal Trigger Sources
Low Power
Low Power
or Convert
or Convert
Track or
Convert
Track Or Convert
1
1
Track
2
2
Track
3
3
4
4
1
5
5
2
6
6
3
7
7
Rev. 1.4
Convert
).
4
8
8
5
9
9
10 11 12 13 14 15 16 17 18 19
10 11 12 13 14 15 16
6
Convert
7
Convert
Convert
8
9
10 11 12 13 14 15 16
Low Power Mode
Track
Low Power Mode
Track
Section