P0080SCMC Littelfuse / Teccor Sidactor(R) Product, P0080SCMC Datasheet - Page 117

no-image

P0080SCMC

Manufacturer Part Number
P0080SCMC
Description
SIDACTOR MC BI 6V 400A DO-214AA
Manufacturer
Littelfuse / Teccor Sidactor(R) Product
Series
SIDACtor® SC(MC)r
Datasheet

Specifications of P0080SCMC

Voltage - Breakover
25V
Voltage - Off State
6V
Voltage - On State
5V
Current - Peak Pulse (8 X 20µs)
400A
Current - Peak Pulse (10 X 1000µs)
100A
Current - Hold (ih)
50mA
Number Of Elements
1
Capacitance
75pF
Package / Case
DO-214AA, SMB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P0080SCMC
Manufacturer:
Littelfuse
Quantity:
45 000
Part Number:
P0080SCMCL
Manufacturer:
Littelfu
Quantity:
150 000
Part Number:
P0080SCMCLRP
Manufacturer:
Littelfu
Quantity:
73 500
Part Number:
P0080SCMCLRP
Manufacturer:
LITTELFUSE/力特
Quantity:
20 000
Part Number:
P0080SCMCRP
Manufacturer:
Littelfu
Quantity:
30 000
Primary Protection
© 2002 Teccor Electronics
SIDACtor
®
Data Book and Design Guide
Primary telecommunications protectors must be deployed at points where exposed twisted
pairs enter an office building or residence. This requirement is mandated in North America
by the National Electric Code (NEC) to protect end users from the hazards associated with
lightning and power cross conditions.
Primary protection is provided by the local exchange carrier and can be segregated into
three distinct categories:
• Station protection — typically associated with a single twisted pair
• Building entrance protection — typically associated with multiple (25 or more) twisted
• Central office protection — typically associated with numerous twisted pair feeding into a
Station protectors provide primary protection for a single-dwelling residence or office. The
station protector is located at the Network Interface Unit (NIU), which acts as the point of
demarcation, separating the operating company’s lines from the customer’s.
Building entrance protection is accomplished by installing a multi-line distribution panel with
integrated overvoltage protection. These panels are normally located where multiple twisted
pairs enter a building.
A five-pin protection module plugged into a Main Distribution Frame (MDF) provides Central
and Remote Office protection. Like station and building entrance protection, the MDF is
located where exposed cables enter the switching office.
Teccor also offers a full line of five-pin protectors. For further details, contact factory at
protectionsystems@teccor.com or +1 972-580-7777.
Protection Requirements
Station protectors must be able to withstand 300 A 10x1000 surge events. The building
entrance protectors and CO protectors must be able to withstand 100 A 10x1000 surge
events. Figure 3.36 shows building entrance protector and CO protector asymmetrical
solutions. Figure 3.37 shows building entrance protector and CO protector balanced
solutions.
The following regulatory requirements apply:
• UL 497
• GR 974-CORE
• ITU K.28
Primary Protection Reference Circuit
Figure 3.36 and Figure 3.37 show different configurations used in primary protection. Note
that the peak off-state voltage (V
applications should be greater than the potential of a Type B ringer superimposed on a
POTS (plain old telephone service) battery.
pair
switch
150 V
RMS
Ö2 + 56.6 V
PK
= 268.8 V
DRM
3 - 29
) of any device intended for use in primary protection
PK
http://www.teccor.com
Primary Protection
+1 972-580-7777

Related parts for P0080SCMC