XBP24-AWI-001 Digi International/Maxstream, XBP24-AWI-001 Datasheet - Page 35

no-image

XBP24-AWI-001

Manufacturer Part Number
XBP24-AWI-001
Description
MODULE 802.15.4 100MW WIRE ANT
Manufacturer
Digi International/Maxstream
Series
XBEE-PRO™r
Datasheets

Specifications of XBP24-AWI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
20dBm (100mW)
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Current - Transmitting
215mA @ 3.3V
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Wire Whip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XBP24-AWI-001
Manufacturer:
MOT
Quantity:
21
AT Command Options
Table 3‐08. XBee®/XBee‐PRO® Commands ‐ AT Command Options
 * Firmware version in which the command was first introduced (firmware versions are numbered in hexadecimal notation.)
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
AT
Command
CT
CN
AC (v1.xA0*)
GT
CC
Command
Category
AT Command
Mode Options
AT Command
Mode Options
AT Command
Mode Options
AT Command
Mode Options
AT Command
Mode Options
Name and Description
Command Mode Timeout. Set/Read the period of inactivity (no valid commands
received) after which the RF module automatically exits AT Command Mode and
returns to Idle Mode.
Exit Command Mode. Explicitly exit the module from AT Command Mode.
Apply Changes. Explicitly apply changes to queued parameter value(s) and re-
initialize module.
Guard Times. Set required period of silence before and after the Command Sequence
Characters of the AT Command Mode Sequence (GT+ CC + GT). The period of silence
is used to prevent inadvertent entrance into AT Command Mode.
Command Sequence Character. Set/Read the ASCII character value to be used
between Guard Times of the AT Command Mode Sequence (GT+CC+GT). The AT
Command Mode Sequence enters the RF module into AT Command Mode.
© 2009 Digi Internatonal, Inc.
Parameter Range
2 - 0xFFFF [x 100 ms]
--
--
2 - 0x0CE4 [x 1 ms]
0 - 0xFF
Default
0x64 (100d)
--
--
0x3E8
(1000d)
0x2B
(‘+’ ASCII)
     35

Related parts for XBP24-AWI-001