XBP24-AWI-001 Digi International/Maxstream, XBP24-AWI-001 Datasheet - Page 53

no-image

XBP24-AWI-001

Manufacturer Part Number
XBP24-AWI-001
Description
MODULE 802.15.4 100MW WIRE ANT
Manufacturer
Digi International/Maxstream
Series
XBEE-PRO™r
Datasheets

Specifications of XBP24-AWI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
20dBm (100mW)
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Current - Transmitting
215mA @ 3.3V
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Wire Whip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XBP24-AWI-001
Manufacturer:
MOT
Quantity:
21
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
SC (Scan Channels) Command
SD (Scan Duration) Command
SH (Serial Number High) Command
SL (Serial Number Low) Command
<Networking {Association}> The SC command is
used to set and read the list of channels to scan
for all Active and Energy Scans as a bit field.
This affects scans initiated in command mode [AS
(Active Scan) and ED (Energy Scan) commands]
and during End Device Association and Coordina-
tor startup.
<Networking {Association}> The SD command is
used to set and read the exponent value that
determines the duration (in time) of a scan.
End Device (Duration of Active Scan during
Association) - In a Beacon system, set SD = BE of
the Coordinator. SD must be set at least to the
highest BE parameter of any Beaconing Coordina-
tor with which an End Device or Coordinator wish
to discover.
Coordinator - If the ‘ReassignPANID’ option is set on the Coordinator [refer to A2 parameter], the
SD parameter determines the length of time the Coordinator will scan channels to locate existing
PANs. If the ‘ReassignChannel’ option is set, SD determines how long the Coordinator will perform
an Energy Scan to determine which channel it will operate on.
Scan Time is measured as ((# of Channels to Scan) * (2 ^ SD) * 15.36ms). The number of chan-
nels to scan is set by the SC command. The XBee RF Module can scan up to 16 channels (SC =
0xFFFF). The XBee PRO RF Module can scan up to 12 channels (SC = 0x1FFE).
Examples: Values below show results for a 12‐channel scan  
<Diagnostics> The SH command is used to read
the high 32 bits of the RF module's unique IEEE
64-bit address.
The module serial number is set at the factory
and is read-only.
<Diagnostics> The SL command is used to read
the low 32 bits of the RF module's unique IEEE
64-bit address.
The module serial number is set at the factory
and is read-only.
If SD = 0, time = 0.18 sec
SD = 2, time = 0.74 sec
SD = 4, time = 2.95 sec
SD = 6, time = 11.80 sec
© 2009 Digi Internatonal, Inc.
bit 0 - 0x0B
bit 1 - 0x0C
bit 2 - 0x0D
bit 3 - 0x0E
bit 4 - 0x0F
bit 5 - 0x10
bit 6 - 0x11
bit 7 - 0x12
SD = 8, time = 47.19 sec
SD = 10, time = 3.15 min
SD = 12, time = 12.58 min
SD = 14, time = 50.33 min
bit 8 - 0x13
bit 9 - 0x14
bit 10 - 0x15
bit 11 - 0x16
AT Command: ATSH
Parameter Range: 0 - 0xFFFFFFFF [read-only]
Related Commands: SL (Serial Number Low),
MY (Source Address)
AT Command: ATSL
Parameter Range: 0 - 0xFFFFFFFF [read-only]
Related Commands: SH (Serial Number High),
MY (Source Address)
AT Command: ATSC
Parameter Range: 1-0xFFFF [Bitfield]
(bits 0, 14, 15 are not allowed when using the
XBee-PRO)
Default Parameter Value: 0x1FFE (all XBee-
PRO channels)
Related Commands: ED (Energy Scan), SD
(Scan Duration)
Minimum Firmware Version Required: v1.x80
AT Command: ATSD
Parameter Range: 0 - 0x0F
Default Parameter Value: 4
Related Commands: ED (Energy Scan), SC
(Scan Channel)
Minimum Firmware Version Required: v1.x80
bit 12 - 0x17
bit 13 - 0x18
bit 14 - 0x19
bit 15 - 0x1A
     53