XBP24-AWI-001 Digi International/Maxstream, XBP24-AWI-001 Datasheet - Page 58

no-image

XBP24-AWI-001

Manufacturer Part Number
XBP24-AWI-001
Description
MODULE 802.15.4 100MW WIRE ANT
Manufacturer
Digi International/Maxstream
Series
XBEE-PRO™r
Datasheets

Specifications of XBP24-AWI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
20dBm (100mW)
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Current - Transmitting
215mA @ 3.3V
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Wire Whip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XBP24-AWI-001
Manufacturer:
MOT
Quantity:
21
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
Start Delimiter
(Byte 1)
0x7E
Start Delimiter
0 x7E
API Types
Checksum
Modem Status
MSB
Data bytes that need to be escaped:
Note: In the above example, the length of the raw data (excluding the checksum) is 0x0002 and
the checksum of the non-escaped data (excluding frame delimiter and length) is calculated as:
0xFF - (0x23 + 0x11) = (0xFF - 0x34) = 0xCB.
To test data integrity, a checksum is calculated and verified on non-escaped data.
To calculate: Not including frame delimiters and length, add all bytes keeping only the lowest 8
bits of the result and subtract from 0xFF.
To verify: Add all bytes (include checksum, but not the delimiter and length). If the checksum is
correct, the sum will equal 0xFF.
Frame data of the UART data frame forms an API-specific structure as follows:
Figure 3‐03. UART Data Frame & API‐specific Structure:
The cmdID frame (API-identifier) indicates which API messages will be contained in the cmdData
frame (Identifier-specific data). Refer to the sections that follow for more information regarding
the supported API types. Note that multi-byte values are sent big endian.
API Identifier: 0x8A
RF module status messages are sent from the module in response to specific conditions.
Figure 3‐04.  Modem Status Frames
Example - Raw UART Data Frame (before escaping interfering bytes):
0x11 needs to be escaped which results in the following frame:
0x7E 0x00 0x02 0x23 0x7D 0x31 0xCB
© 2009 Digi Internatonal, Inc.
(Bytes 2-3)
• 0x7E – Frame Delimiter
• 0x7D – Escape
• 0x11 – XON
• 0x13 – XOFF
Length
MSB
Length
LSB
API Identifier
0x7E 0x00 0x02 0x23 0x11 0xCB
LSB
cmdID
API Identifier
0x8 A
API-specific Structure
API -specific Structure
Frame Data
(Bytes 4- n)
0 = Hardware reset
1 = W atchdog timer reset
2 = Associated
3 = Disassociated
4 = Synchronization Lost
5 = Coordinator realignment
6 = Coordinator started
Frame Data
Identifier-specific Data
( Beacon -enabled only )
Identifier-specific Data
cmdData
Status (Byte 5 )
cmdData
(Byte n + 1)
Checksum
1 Byte
Checksum
1 Byte
     58