SI4030-A0-FM Silicon Laboratories Inc, SI4030-A0-FM Datasheet - Page 36

IC TX ISM 930MHZ 3.6V 20-QFN

SI4030-A0-FM

Manufacturer Part Number
SI4030-A0-FM
Description
IC TX ISM 930MHZ 3.6V 20-QFN
Manufacturer
Silicon Laboratories Inc
Type
ISM Transmitterr
Datasheets

Specifications of SI4030-A0-FM

Package / Case
20-QFN
Frequency
240MHz ~ 930MHz
Modulation Or Protocol
FSK, GFSK, OOK
Data Rate - Maximum
128kbps
Power - Output
20dBm (100mW)
Current - Transmitting
28mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Voltage - Supply
1.8 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Operating Frequency
240 MHz to 960 MHz
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Supply Current
100 nA
Supply Voltage (max)
3.6 V
Supply Voltage (min)
1.8 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Applications
-
Memory Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
336-1624-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI4030-A0-FM
Manufacturer:
SILICON
Quantity:
120
Part Number:
SI4030-A0-FM
Manufacturer:
SILICONLABS/芯科
Quantity:
20 000
Si4330-B1
6.4. Data Whitening, Manchester Encoding, and CRC
Data whitening can be used to avoid extended sequences of 0s or 1s in the transmitted data stream to achieve a
more uniform spectrum. When enabled, the payload data bits are XORed with a pseudorandom sequence output
from the built-in PN9 generator. The generator is initialized at the beginning of the payload. The receiver recovers
the original data by repeating this operation. Manchester encoding can be used to ensure a dc-free transmission
and good synchronization properties. When Manchester encoding is used, the effective datarate is unchanged but
the actual datarate (preamble length, etc.) is doubled due to the nature of the encoding. The effective datarate
when using Manchester encoding is limited to 128 kbps. The implementation of Manchester encoding is shown in
Figure 16. Data whitening and Manchester encoding can be selected with "Register 70h. Modulation Mode Control
1". The CRC is configured via "Register 30h. Data Access Control." Figure 15 demonstrates the portions of the
packet which have Manchester encoding, data whitening, and CRC applied. CRC can be applied to only the data
portion of the packet or to the data, packet length and header fields. Figure 16 provides an example of how the
Manchester encoding is done and also the use of the Manchester invert (enmaniv) function.
6.5. Preamble Detector
The Si4330 has integrated automatic preamble detection. The preamble length is configurable from 1–256 bytes
using the prealen[7:0] field in "Register 33h. Header Control 2" and "Register 34h. Preamble Length," as described
in “6.2. Packet Configuration.” The preamble detection threshold, preath[4:0] as set in "Register 35h. Preamble
Detection Control 1", is in units of 4 bits. The preamble detector searches for a preamble pattern with a length of
preath[4:0].
If a false preamble detect occurs, the receiver will continuing searching for the preamble when no sync word is
detected. When a false preamble detect occurs, the receiver will continuing searching for the preamble when no
sync word is detected. Once preamble is detected (false or real) then the part will then start searching for sync. If
no sync occurs then a timeout will occur and the device will initiate search for preamble again. The timeout period
is defined as the sync word length plus four bits and will start after a non-preamble pattern is recognized after a
valid preamble detection. The preamble detector output may be programmed onto one of the GPIO or read in the
interrupt status registers.
36
1
0
1
0
Figure 15. Operation of Data Whitening, Manchester Encoding, and CRC
1
0
Preamble = 0xFF
Preamble = 0x00
1
0
Preamble
1
0
1
0
Figure 16. Manchester Coding Example
1
0
Sync
1
0
Address
0
0
Header/
First 4bits of the synch. word = 0x2
First 4bits of the synch. word = 0x2
Manchester
Rev 1.0
0
0
0
0
Length
CRC
PK
Whitening
1
1
(Over data only)
0
0
Data
CRC
Data before Manchester
Data after Machester ( manppol = 1, enmaninv = 0)
Data after Machester ( manppol = 1, enmaninv = 1)
Data before Manchester
Data after Machester ( manppol = 0, enmaninv = 0)
Data after Machester ( manppol = 0, enmaninv = 1)
CRC

Related parts for SI4030-A0-FM