CM600HU-12F Powerex Inc, CM600HU-12F Datasheet
CM600HU-12F
Specifications of CM600HU-12F
CM600HU-12F
Available stocks
Related parts for CM600HU-12F
CM600HU-12F Summary of contents
Page 1
... Isolated Baseplate for Easy Heat Sinking Applications: AC Motor Control UPS Battery Powered Supplies Ordering Information: Example: Select the complete module number you desire from the table - i.e. CM600HU-12F is a 600V (V ), 600 Ampere Dual CES IGBTMOD™ Power Module. Current Rating V CES Type ...
Page 2
... GES 60mA 10V GE(th 600A 15V, T CE(sat 600A 15V 300V 600A 600A does not exceed T j CM600HU-12F -40 to 150 -40 to 125 600 20 600 1200* 600 1200* 1420 450 2500 Min. Typ. Max – – – – – 1.6 2 125 C – 1.6 – ...
Page 3
... Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM600HU-12F Trench Gate Design Single IGBTMOD™ 600 Amperes/600 Volts Dynamic Electrical Characteristics, T Characteristics Input Capacitance Output Capacitance Reverse Transfer Capacitance Inductive Turn-on Delay Time Load Rise Time Switch Turn-off Delay Time ...
Page 4
... Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM600HU-12F Trench Gate Design Single IGBTMOD™ 600 Amperes/600 Volts OUTPUT CHARACTERISTICS (TYPICAL) 1200 9 1000 V = 20V GE 800 9 600 8.5 400 8 200 7 COLLECTOR-EMITTER VOLTAGE (VOLTS) CE FREE-WHEEL DIODE FORWARD CHARACTERISTICS (TYPICAL 1.0 2.0 3 ...