XRT5894IV-F Exar Corporation, XRT5894IV-F Datasheet - Page 14

IC LIU E1 QUAD 64TQFP

XRT5894IV-F

Manufacturer Part Number
XRT5894IV-F
Description
IC LIU E1 QUAD 64TQFP
Manufacturer
Exar Corporation
Datasheet

Specifications of XRT5894IV-F

Maximum Operating Temperature
+ 85 C
Maximum Power Dissipation
590 mW / 1240 mW
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
3.3 V / 5 V
Package / Case
TQFP-64
Supply Voltage Range
3.135V To 3.465V, 4.75V To 5.25
Power Dissipation Pd
1240mW
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
TQFP
No. Of Pins
64
Filter Terminals
SMD
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XRT5894IV-F
Manufacturer:
EXAR
Quantity:
1 558
Part Number:
XRT5894IV-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
XRT5894IV-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Transmitter Output Return Loss Measurements
The following measurements were made with a Wandel
and Goltermann SNA--2 Network Analyzer equipped with
an RFZ--1 75W Return Loss Bridge. A 75W to 120W
impedance matching transformer was used to make the
120W measurement. A network analyzer calibration run
subtracted out the effects of this transformer.
Test Conditions:
D Output transformer ratio was 1:2.
D Transmitter series resistors (R3 and R4 in Figure 1)
D Device was powered from a 3.3V source, transmitter
Notes:
XRT5894
fb = 2048KHz
This data shows that the XRT5894 is fully compliant with the ETSI Output Return Loss Specification for E1 operation with either
75W or 120W loads.
were 9.1W .
was enabled, and no output data was present.
Rev. 1.10
Frequency
Specified
0.025 fb
0.05 fb
1.5 fb
Table 5. Transmitter Output Return Loss Measurements
Frequency
(KHz)
102.4
3072
51.2
ETSI Spec.
(Min. dB)
6
8
8
14
This configuration was used for both 75W and 120W
measurements. The only change was the termination
resistance provided by the return loss bridge.
Test Results:
Table 5 compares measured output return loss with
requirements in ETSI FINAL DRAFT prETS 300 166,
June 1993. These results show that measured return loss
is mainly determined by the characteristics of the output
transformer. This is particularly evident for the 120W load
where the measured result is better than the calculated
value.
Meas. Value (dB)
75W Load
22.6
22.6
18.0
Meas. Value (dB)
120W Load
15.4
15.7
14.6