BH1620FVC-TR Rohm Semiconductor, BH1620FVC-TR Datasheet - Page 5

Industrial Optical Sensors Ambient Light Sensor Analog Curr Output

BH1620FVC-TR

Manufacturer Part Number
BH1620FVC-TR
Description
Industrial Optical Sensors Ambient Light Sensor Analog Curr Output
Manufacturer
Rohm Semiconductor
Type
Ambient Light Sensor with Analog Outputr
Datasheet

Specifications of BH1620FVC-TR

Product
Ambient Light Sensor
Wavelength
560nm
Output Type
I²C™
Package / Case
SOT-665
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BH1620FVC-TR
Manufacturer:
ROHM/罗姆
Quantity:
20 000
© 2009 ROHM Co., Ltd. All rights reserved.
BH1620FVC
www.rohm.com
External parts Setting
1) Gain setting of BH1620FVC
2) Approximate formula of IOUT output voltage in each Gain Mode
3) C1
Please select the best gain controlled by 3 and 4pin based on the required illuminance range.
The reference is as follows.
This device will be mounted under the optical window in actual designing. Therefore, there is a possibility that the
illuminace to ALS( Ambient Light Sensor) will be less than the illuminance on the final product surface. Please consider the
attenuation of light through the optical window. Please set output resistance value( R1) within the range of 1 kΩ~1MΩ
which needs to be smaller than the input impedance of the next circuit.
(1) H-Gain mode
(2) M-Gain mode
(3) L-Gain mode
(1) To reject the flicker light..
(2) To control backlight smoothly by using illuminance value.
The output voltage is calculated as below.
Viout= 0.57 x 10
Viout is IOUT output voltage [V]. Ev is an illuminance of the ALS surface [lx].
(For example) In case you want to convert the illuminance value up to 500 lx by ADC.
If the maximum voltage of ADC input is 2V, output resistor value will be as below.
Viout= 0.057 x 10
Viout= 0.0057 x 10
In case IOUT output is R1 only and an ALS receives the artificial lights such as fluorescent lamps and incandescent
lamps synchronized with 50/60 Hz of AC power supplies, the output current has a ripple. If you want to reject this ripple,
please add C1 to R1 in parallel. Please set it to C1 x R1 = about 0.1 as a time constant.
C1 is effective to control backlight smoothly for a rapid changing of the illuminance. In this case, please set it to
C1 x R1 = about 1 ~ 10 as a time constant. It is not necessary if you average illuminance value with software to change
backlight smoothly.
Please note that the rise time becomes slow at power-on and recovery from shutdown mode to operation mode.
Illuminance detection range [lx]
R1 is IOUT output resistor[Ω].
R1 = Viout/(0.57 x 10
= 2 /(0.57 x 10
~100,000
~10,000
~1,000
-6
-6
x Ev x R1
-6
-6
x Ev x R1
x Ev x R1
x 500) = 7018[Ω]
-6
x Ev)
⇒6.8[kΩ]
M-Gain Mode
H-Gain Mode
L-Gain Mode
Gain Mode