Specifications of TSL2561T

Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 30 C
Mounting Style
SMD/SMT
Package / Case
TMB
Response Time
400ms
Output Current
6mA
Supply Voltage Range Dc
2.7V To 3.6V
Supply Current
0.6mA
Operating Temperature Range
-30°C To +70°C
Operating Temperature Min
-30°C
Rohs Compliant
Yes
Operating Temperature Max
70°C
Sensor Output
I2C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TSL2561T
Manufacturer:
IR
Quantity:
836
Part Number:
TSL2561T
Manufacturer:
AMS
Quantity:
20 000
Part Number:
TSL2561T
0
TSL2560, TSL2561
LIGHT-TO-DIGITAL CONVERTER
TAOS059N − MARCH 2009
Command Register
NOTE: An I
Control Register (0h)
14
Copyright E 2009, TAOS Inc.
ADDRESS
Reset Value:
Reset Value:
POWER
BLOCK
CLEAR
WORD
FIELD
FIELD
CMD
Resv
The command register specifies the address of the target register for subsequent read and write operations.
The Send Byte protocol is used to configure the COMMAND register. The command register contains eight bits
as described in Table 3. The command register defaults to 00h at power on.
The CONTROL register contains two bits and is primarily used to power the TSL256x device up and down as
shown in Table 4.
SMBus read/write protocol requires a Byte Count. All four ADC Channel Data Registers (Ch through Fh) can be read simultaneously in
a single SMBus transaction. This is the only 32-bit data block supported by the TSL2560 SMBus protocol. The BLOCK bit must be set
to 1, and a read condition should be initiated with a COMMAND CODE of 9Bh. By using a COMMAND CODE of 9Bh during an SMBus
Block Read Protocol, the TSL2560 device will automatically insert the appropriate Byte Count (Byte Count = 4) as illustrated in Figure 17.
A write condition should not be used in conjunction with the Bh register.
0h
2
C block transaction will continue until the Master sends a stop condition. See Figure 16 and Figure 17. Unlike the I2C protocol, the
CMD
Resv
BIT
BIT
3:0
7:2
1:0
7
7
6
5
4
7
0
0
Select command register. Must write as 1.
Interrupt clear. Clears any pending interrupt. This bit is a write-one-to-clear bit. It is self clearing.
SMB Write/Read Word Protocol. 1 indicates that this SMB transaction is using either the SMB Write Word or
Read Word protocol.
Block Write/Read Protocol. 1 indicates that this transaction is using either the Block Write or the Block Read
protocol. See Note below.
Register Address. This field selects the specific control or status register for following write and read
commands according to Table 2.
Reserved. Write as 0.
Power up/power down. By writing a 03h to this register, the device is powered up. By writing a 00h to this
register, the device is powered down.
NOTE: If a value of 03h is written, the value returned during a read cycle will be 03h. This feature can be
used to verify that the device is communicating properly.
CLEAR
Resv
6
0
6
0
WORD
Resv
0
0
5
5
r
Table 3. Command Register