914CE2-9 Honeywell, 914CE2-9 Datasheet - Page 103

no-image

914CE2-9

Manufacturer Part Number
914CE2-9
Description
Basic / Snap Action / Limit Switches 1NC/1NO 9' cable SPDT
Manufacturer
Honeywell
Type
Limitr
Datasheets

Specifications of 914CE2-9

Contact Form
SPDT - 1 NC / 1 NO
Contact Rating
5 Amps
Actuator
Plunger, Roller
Ingress Protection
IP66 / IP67 / IP68
Operating Force
11.8 N
Termination Style
Wire
Actuator Type
Roller Plunger
Body Style
Miniature
Current, Rating
5 A
Ip Rating
IP68
Mounting Hole Size
0.2 "
Number Of Poles
1
Number Of Positions
2
Temperature, Operating
0 to +70 °C
Termination
Cable
Voltage, Rating
240 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
AQLT Series
Housing length:
Mechanical travel:
ELECTRICAL TRAVEL
(MM (IN))
152,4 (6.0)
304,8 (12.0)
457,2 (18.0)
609,6 (24.0)
762,0 (30.0)
965,2 (38.0)
AQLT/AQMLT Series
Shaftless, waterproof linear position
transducer
BOLT CIRCLE
Dimensions in inches (mm)
Ø 0.156
(3,96)
Ø 0.813
(20,65)
3 WIRE JACKETED CABLE (9/64 Ø)
#28 AWG CONDUCTOR
10 FEET LONG
COLOR CODED PER SCHEMATIC
120˚
Ø 0.516
TOTAL RESISTANCE
(OHM)
6000
12000
18000
24000
30000
38000
(13,11)
(19,30)
WITHOUT RESTRICTING ELECTRICAL TRAVEL
0.76
#4-40 UNC THD
6 PLACES
AREA AVAILABLE FOR CLAMPING
(31,75)
Ø 1.25
ELECTRICAL TRAVEL
PLUS 2.16" (54,86)
0.024 (0,61)
OFF CENTER
120˚
= Electrical travel + 54,87 mm (2.16 in)
= Electrical travel + 2,54 mm (0.1 in)
REFERENCE
AQLT06N06KFC
AQLT12N12KFC
AQLT18N18KFC
AQLT24N24KFC
AQLT30N30KFC
AQLT38N38KFC
CABLE END
(25,4 ±0,25)
1.00 ±0.010
(12,70)
BLACK
0.50
0.25
(6,35)
www.honeywell.com/sensing
BROWN
(28,575 ±0,25)
1.125 ±0.010
(5,08)
0.20
RED
Ø 0.50
(12,7)
The AQLT and AQMLT are shaftless waterproof linear potentiometers designed
to operate in wet/washdown and in-tank environments.
The AQ series features an external actuator magnetically coupled to a position
feedback element. The magnetic actuator replaces the shaft, found in
traditional linear transducers, and eliminates the need for additional stroke
length mounting space.
Precious metal dual wipers, MystR
anodized aluminum housings provide long life and reliable operation in
numerous applications.
Operating temperature:
Supply voltage (max.):
Linearity:
Starting force (max.):
Sealing:
Termination:
AQMLT Series
Housing length:
Mechanical travel:
ELECTRICAL TRAVEL
(MM (IN))
12,7 (0.5)
25,4 (1.0)
76,2 (3.0)
152,4 (6.0)
228,6 (9.0)
304,8 (12.0)
Ø 0.156
Dimensions are in inches (mm)
(3,96)
120˚
BOLT CIRCLE
Ø 1.125
3 WIRE JACKETED CABLE, Ø 0.14 (3,57)
#28 AWG CONDUCTOR
10 FEET LONG (3,05 M)
COLOR CODED PER SCHEMATIC
(28,58)
Ø 0.690
(17,53)
(13,2)
0.52
TOTAL RESISTANCE
(OHM)
750
1500
3000
9000
13500
18000
ELECTRICAL TRAVEL PLUS 1.5 (38,1) MAX
WITHOUT RESTRICTING ELECTRICAL OR
LINEAR AND ROTARY POSITION
AREA AVAILABLE FOR CLAMPING
MECHANICAL TRAVEL
Ø 0.388
®
(9,78)
proprietary conductive plastic, and
120˚
= Electrical travel + 2,54 mm (0.1 in)
= Electrical travel + 38,1 mm (1.5 in)
REFERENCE
AQMLTR5N00750FC
AQMLT01N01500FC
AQMLT03N04500FC
AQMLT06N09000FC
AQMLT09N13500FC
AQMLT12N18000FC
OFF CENTER
-40 °C to 80 °C (-40 °F to 176 °F)
(3,18)
0.125
(0,60)
0.024
Cable End
AQMLT
#4-40 UNC THD
AQMT
0.20
(5,1)
Black
4 PLACES
(12,70)
0.500
Brown
Wiper
Schematic
28,35 g (1.0 oz)
56,7 g (2.0 oz)
(25,40)
(6,35)
0.250
1.000
Ø 0.375
Red
± 1.0 %
(9,5)
30 Vdc
Cable
IP68
101