914CE2-9 Honeywell, 914CE2-9 Datasheet - Page 142

no-image

914CE2-9

Manufacturer Part Number
914CE2-9
Description
Basic / Snap Action / Limit Switches 1NC/1NO 9' cable SPDT
Manufacturer
Honeywell
Type
Limitr
Datasheets

Specifications of 914CE2-9

Contact Form
SPDT - 1 NC / 1 NO
Contact Rating
5 Amps
Actuator
Plunger, Roller
Ingress Protection
IP66 / IP67 / IP68
Operating Force
11.8 N
Termination Style
Wire
Actuator Type
Roller Plunger
Body Style
Miniature
Current, Rating
5 A
Ip Rating
IP68
Mounting Hole Size
0.2 "
Number Of Poles
1
Number Of Positions
2
Temperature, Operating
0 to +70 °C
Termination
Cable
Voltage, Rating
240 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PRESSURE SENSORS
TLD Series
140
OPTIONS
Flow-through/Output Signal 4 mA to 20 mA
MEASUREMENT TYPE
Compound
Compound
Compound
Flow-through/Output Signal 0 Vdc to 5.0 Vdc
MEASUREMENT TYPE
Compound
Single Port/Output Signal 4 mA to 20 mA
MEASUREMENT TYPE
Compound
With space at a premium in semiconductor gas distribution systems, the Series TLD pressure transducer with local
display offers an integrated solution that reduces the overall height of the transducer/display assembly to as little as 3.5
in [88,9 mm]. To accomplish this, the transducer’s signal amplifier is mounted within the display, with the added benefit
of zero and span adjustments conveniently located on the LED display face.
Supply voltage:
Signal conditioning:
Operating temperature range:
Compensated temperature range:
Termination type:
BF - Transducer at bottom, front display orientation
BS - Transducer at bottom, side display orientation
z
38,1
1.50
35,9
1.42
s
www.honeywell.com/sensing
82,5
3.25
26,1
1.03
82,5
3.25
Flow-through display orientation and transducer location
72,4
2.85
72,4
2.85
PRESSURE RANGE
-14.7 psig to 100 psig
-14.7 psig to 100 psig
-14.7 psig to 100 psig
PRESSURE RANGE
-14.7 psig to 100 psig
PRESSURE RANGE
-14.7 psig to 100 psig
38,1
1.50
38,1
1.50
26,1
1.03
z
35,9
1.42
38,1
1.50
s
CABLE
2 COND
1,8 m (6 ft)
1/4 in. OD 0.035 in. wall, 1/4 in long tube stub
1/4 in. female face seal, swivel
1/4 in. female face seal, swivel
1/4 in. OD 0.035 in. wall, 1/4 in long tube stub
1/4 in. female face seal, swivel
CONNECTIONS
CONNECTIONS
CABLE
2 COND
1,8 m (6 ft)
CV - Transducer at center back,
vertical display orientation
CH - Transducer at center back,
horizontal display orientation
77,0
3.03
42,7
1.68
-40 °C to 85 °C (-40 °F to 185 °F)
1,83 m (6 ft) 2-conductor cable
0 °C to 70 °C (32 °F to 158 °F)
z
38,1
1.50
38,1
1.50
REFERENCE
TLDF4CVT4V100CP
TLDF4CVVFV100CP
TLDF4BSVFV100CP
REFERENCE
TLDF5CVT4V100CP
REFERENCE
TLDS4BNVFV100CP
s
Amplified compensated
12.0 Vdc to 30.0 Vdc
CABLE
2 COND
1,8 m (6 ft)
38,1
1.50
38,1
1.50

Related parts for 914CE2-9