914CE2-9 Honeywell, 914CE2-9 Datasheet - Page 82

no-image

914CE2-9

Manufacturer Part Number
914CE2-9
Description
Basic / Snap Action / Limit Switches 1NC/1NO 9' cable SPDT
Manufacturer
Honeywell
Type
Limitr
Datasheets

Specifications of 914CE2-9

Contact Form
SPDT - 1 NC / 1 NO
Contact Rating
5 Amps
Actuator
Plunger, Roller
Ingress Protection
IP66 / IP67 / IP68
Operating Force
11.8 N
Termination Style
Wire
Actuator Type
Roller Plunger
Body Style
Miniature
Current, Rating
5 A
Ip Rating
IP68
Mounting Hole Size
0.2 "
Number Of Poles
1
Number Of Positions
2
Temperature, Operating
0 to +70 °C
Termination
Cable
Voltage, Rating
240 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SAFETY SWITCHES
GSS Series
Hinge Mount Safety
Limit Switch
80
The Hinge Mount Safety Limit Switch is designed for use on machine access doors as an alternative solution
to key operated interlocks and safety limit switches. When the access door is opened, a follower pin (not
supplied) slides down the slot in the actuator lever, forcing the actuator lever to rotate and positively open the
NC safety circuit to shut off the machine. Closing the access door rotates the actuator lever to the reset
position, closing the NC safety contacts.
The Hinge Mount Safety Limit Switch minimizes alignment problems because it may be offset-mounted from
the hinge point of the door. The tamper-resistant design and the positive opening contacts provide a higher
level of safety than the conventional spring-driven limit switches often used to monitor door position.
Low Energy Switching
In today’s demanding age of low energy controls, electromechanical switches are frequently used to interface
directly with safety relays, PLCs and other low energy devices. To accommodate this requirement GSS offers
a new gold plated contact version of the standard basic switch. This improves reliability of switching at low
currents and voltages by protecting the contact surfaces from contamination during operation or storage
prior to use.
Standard silver contacts have a disadvantage in that the contact surface may tarnish under certain
environmental conditions, e.g. in the presence of moisture.
Low energy basic switches are rated as follows:
Operating Voltage U
Operating Current I
Example of catalog listing using a low energy basic switch - GSCB33S2.
Switching options:
Snap action contacts (1NC/1NO)
Slow action contacts (1NC/1NO) BBM
Slow action contacts (2NC)
Electrical ratings:
Designation & Utilization
www.honeywell.com/sensing
AC15
AC15
AC15
AC14
DC13
DC13
11
21
13
21
13
21
Category
A600
A300
B300
D300
Q300
R300
14
22
12
22
Zb
2Y
22
14
e
Zb
e
GSC/D
120 V
125 V
0,55
0,22
0,6
6
6
3
IEC 60947-5-1/EN 60947-5-1
1 Vdc to 60 Vdc or 1 Vac to 125 Vac
1 mA to 50 mA
240 V
250 V
Rated operational current le (A)
0,27
at rated operational voltage Ue
1.5
0,3
0,1
3
3
380 V
1,9
-
-
-
480 V
1,5
-
-
-
500 V
1,4
-
-
-
Slow action contacts (3NC/1NO) BBM
Slow action contacts (4NC)
Slow action contacts (2NC/2NO) BBM
600 V
1,2
-
-
-
11
31
41
21
33
43
11
21
31
43
11
21
Make
7200
7200
3600
432
69
28
rating
12
22
32
44
VA
34
44
12
22
32 4Y
42
12
22
3Y, 1X
Break
2Y, 2X
720
720
360
72
69
28
GSE