DS1822+ Maxim Integrated Products, DS1822+ Datasheet - Page 9

Board Mount Temperature Sensors IC THERMOMETER ECONO DIG

DS1822+

Manufacturer Part Number
DS1822+
Description
Board Mount Temperature Sensors IC THERMOMETER ECONO DIG
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1822+

Temperature Threshold
Programmable
Full Temp Accuracy
+/- 2 C
Package / Case
TO-92
Digital Output - Bus Interface
1-Wire
Digital Output - Number Of Bits
9 bit to 12 bit
Supply Voltage (max)
5.5 V
Supply Voltage (min)
3 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Output Type
Digital
Supply Current
1.5 mA
Ic Output Type
Digital
Sensing Accuracy Range
± 2°C
Supply Voltage Range
3V To 5.5V
Resolution (bits)
12bit
Sensor Case Style
TO-92
No. Of Pins
3
Accuracy %
2°C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
is available in Application Note 27 entitled Understanding and Using Cyclic Redundancy Checks with
Dallas Semiconductor Touch Memory Products.
CRC GENERATOR Figure 9
1-WIRE BUS SYSTEM
The 1-Wire bus system uses a single bus master to control one or more slave devices. The DS1822 is
always a slave. When there is only one slave on the bus, the system is referred to as a “single-drop”
system; the system is “multidrop” if there are multiple slaves on the bus.
All data and commands are transmitted least significant bit first over the 1-Wire bus.
The following discussion of the 1-Wire bus system is broken down into three topics: hardware
configuration, transaction sequence, and 1-Wire signaling (signal types and timing).
HARDWARE CONFIGURATION
The 1-Wire bus has by definition only a single data line. Each device (master or slave) interfaces to the
data line via an open drain or 3-state port. This allows each device to “release” the data line when the
device is not transmitting data so the bus is available for use by another device. The 1-Wire port of the
DS1822 (the DQ pin) is open drain with an internal circuit equivalent to that shown in Figure 10.
The 1-Wire bus requires an external pullup resistor of approximately 5 kΩ; thus, the idle state for the 1-
Wire bus is high. If for any reason a transaction needs to be suspended, the bus MUST be left in the idle
state if the transaction is to resume. Infinite recovery time can occur between bits so long as the 1-Wire
bus is in the inactive (high) state during the recovery period. If the bus is held low for more than 480μs,
all components on the bus will be reset.
HARDWARE CONFIGURATION Figure 10
(MSB)
T
R
X
X
V
PU
4.7k
R
T
X
X
XOR
= TRANSMIT
= RECEIVE
1-wire Bus
9 of 21
XOR
DQ
Pin
Typ.
5μA
DS1822 1-WIRE PORT
(LSB)
MOSFET
100Ω
T
R
X
X
INPUT
XOR
DS1822