N-1X Triad Magnetics, N-1X Datasheet

Transformers 230/115V 50VA XFMR STEP-UP/STEP-DOWN

N-1X

Manufacturer Part Number
N-1X
Description
Transformers 230/115V 50VA XFMR STEP-UP/STEP-DOWN
Manufacturer
Triad Magnetics
Type
Transformers and Autotransformersr
Datasheets

Specifications of N-1X

Dimensions
93.68 mm W x 57.93 mm H
Product
Auto/Isolation Transformers
Height
57.93 mm
Width
93.68 mm
Brand/series
N Series
Configuration
Bobbin
Current, Secondary
0.435 A
Frequency
50/60 Hz
Mounting Hole Centers
3.125 "
Number Of Outlets
2
Phase
1
Power, Rating
50 VA
Termination
Leadwires
Voltage, Primary
230 VAC
Voltage, Secondary
115 VAC
Weight
1.5 lbs.
Power Rating
50 VA
Primary Voltage Rating
230 V
Mounting Style
Foot
Length
2 in
Termination Style
Wire Leads
Output Voltage
115V
Output Current
0.435A
Transformer Mounting
Chassis
Secondary Current Nom
0.435A
No. Of Phases
Single
Primary Voltages
230V
Mounting Type
Screw
Rohs Compliant
Yes
External Height
2.281"
Connector Type
Wire Leads
Current Rating
0.435A
External Depth
2.000"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
N-1X
Electrical Specifications (@25ºC)
1. Maximum Power:
2. Input Voltage:
3. Output Voltage:
4. Full Secondary Load: 0.87 Amps RMS
Construction:
Single winding on a double wall, nylon bobbin. This chassis mount design
comes in a channel frame with .187” diameter holes in the mounting ears.
Description:
Secondary coil is a fraction of the entire winding for voltage step-down.
This causes part of the power to be transferred conductively through the
windings, rather than all of the power being transferred by induction.
Safety:
These units are designed with 1500V isolation between the winding and the
core. Materials and construction are rated for Class B insulation system.
Dimensions:
Weight: 1.5 lbs
Connections: 7.0±1” leads, 0.250±0.062” Skin & Tin
Schematic:
For 230V input: Blk to Red
For 115 output: Blk to Blk/Red
RoHS Compliance:
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact
Triad Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
2.281
A
3.687
B
As of manufacturing date February 2005, all standard
2.00
Unit: In inches
C
50 VA
230 V, 50 / 60 Hz
115V + 5%
3.125
D
230V
115V
22520B Temescal Canyon Road
Corona, California
92883
OV
BLK/RED
BLK
RED
P
C
HASSIS
O W E R
M
T
OUNT :
R A N S F O R M E R
Publish Date: September 11, 2006
Autotransformer
A
B
D
C