H5CX-AD-N AC24/DC12-24 Omron, H5CX-AD-N AC24/DC12-24 Datasheet - Page 24

Stopwatches / Timers SCREW TERM RLY OUT Multi-Function

H5CX-AD-N AC24/DC12-24

Manufacturer Part Number
H5CX-AD-N AC24/DC12-24
Description
Stopwatches / Timers SCREW TERM RLY OUT Multi-Function
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-AD-N AC24/DC12-24

Timing Range
0.001 s to 9999 Hrs
Supply Voltage
12 V to 24 V
Current Rating (max)
100 mA
Display Type
4 Digit LCD Backlight
Product
Digital Timer
Termination Style
Screw
Time Range
0.001s-9999hrs
Power Consumption
2.4W
Reset Time
20ms
Character Size
11.5mm
Mounting Type
Panel
Time Range Min
0.001s
Supply Voltage Min
12V
Connector Type
Screw Terminal
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12 ~ 24VDC, 24VAC
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
No. Of Digits / Alpha
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
PNP/NPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
24
H5CX-A@-N/-L@-N
Timer
Note: H5CX-L8E@-N Precautions
Instantaneous
Mode E: Interval (Timer resets when power comes ON.)
Basic operation
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Output is not instantaneous when setting is 0.
Mode Z: ON/OFF-duty adjustable flicker (Timer resets when power comes ON.)
Basic operation
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Normal output operation will not be possible if
Instantaneous
Time-limit
Power
Time-limit
output
output
Set the Timer’s set value before using the Timer in a self-holding circuit.
Power
the set time is too short.
Set the value to at least 100 ms.
output
output
Timing (cycle time) Timing (cycle time)
Timing
(ON duty)
Timing
Timing
(ON duty)
Detailed operation
Detailed operation
Instantaneous
Instantaneous
Instantaneous
Instantaneous
contacts, NC
contacts, NO
contacts, NC
contacts, NO
contacts, NC
contacts, NO
contacts, NC
contacts, NO
Reset Key
Reset Key
Time-limit
Time-limit
Time-limit
Time-limit
Power
Power
t-a
t = Set time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.)
t-a
t = Set time, dty = ON duty time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.)
dty
t
t
dty
t-a
Rt
Rt
dty
t
t
dty
t-a
t-a
t-a
Rt
Rt
t-a
t-a