H5CX-AD-N AC24/DC12-24 Omron, H5CX-AD-N AC24/DC12-24 Datasheet - Page 38

Stopwatches / Timers SCREW TERM RLY OUT Multi-Function

H5CX-AD-N AC24/DC12-24

Manufacturer Part Number
H5CX-AD-N AC24/DC12-24
Description
Stopwatches / Timers SCREW TERM RLY OUT Multi-Function
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-AD-N AC24/DC12-24

Timing Range
0.001 s to 9999 Hrs
Supply Voltage
12 V to 24 V
Current Rating (max)
100 mA
Display Type
4 Digit LCD Backlight
Product
Digital Timer
Termination Style
Screw
Time Range
0.001s-9999hrs
Power Consumption
2.4W
Reset Time
20ms
Character Size
11.5mm
Mounting Type
Panel
Time Range Min
0.001s
Supply Voltage Min
12V
Connector Type
Screw Terminal
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12 ~ 24VDC, 24VAC
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
No. Of Digits / Alpha
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
PNP/NPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
38
H5CX-B@-N
Operation in Function Setting Mode
Settings that cannot be performed with the DIP switch are performed with the operation keys.
• Change to Function Setting Mode.
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode.
Run mode
Also, when settings are changed, the timer is reset (time initialized and output turned OFF).
Power ON
Absolute
value setting/
forecast value
setting
Set value
upper limit
Forecast
setting upper
limit
Output 1
(OUT1)
ON count
alarm set value
Output 2
(OUT2)
ON count
alarm set value
Output 1
(OUT1)
ON count
monitor value
Output 2
(OUT2)
ON count
monitor value
3 s min.
3 s min.
Function setting mode
*1
*2
Set the digits for the set values using the
corresponding
Set the digits for the set values using the
corresponding
Set the digits for the set values using the
corresponding
Set the digits for the set values using the
corresponding
Set the digits for the set values using the
corresponding
Note: Displayed only in forecast setting mode.
Note: The monitor value is only displayed. It cannot be set.
Note: The monitor value is only displayed. It cannot be set.
value setting)
(0 x 1000
(0 x 1000
(Forecast
times)
times)
(1)
(1)
~
~
~
~
~
(9999 x 1000
(9999 x 1000
value setting)
(Absolute
(999999)
(999999)
times)
times)
Key.
Key.
Key.
Key.
Key.