83203 SENSONOR TECHNOLOGIES AS, 83203 Datasheet - Page 6

no-image

83203

Manufacturer Part Number
83203
Description
IC, SENSOR, GYRO, SAR10, 16SOIC
Manufacturer
SENSONOR TECHNOLOGIES AS
Datasheet

Specifications of 83203

Sensor Case Style
SOIC
No. Of Pins
16
Supply Voltage Range
4.45V To 5.5V
Operating Temperature Range
-40°C To +90°C
Ic Generic Number
SAR10H
Interface
SPI
Sensitivity
0.03°/
Interface Type
SPI
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4
5
Prolonged exposure to absolute maximum ratings may affect the performance and/or reliability of the device.
Serial data communication with the application is through the SPI interface. The 8 MSBs of an angular rate data
sample are mapped to the 8 bit response of the RARH (read angular rate high byte) command. The 2 LSBs of the
sample are mapped to the 2 LSBs of the 8 bit response of the RARL (read angular rate low byte) command. The
RARH command latches the 2 LSBs of a sample such that a RARH, RARL command sequence guarantees bits from
the same angular rate sample. The 6 MSBs of the response from the RARL command is always a ‘010101’ SPI error
check bit pattern.
5.1
TS1162 rev. 1
Characteristics
Supply voltage
Input voltage, any pin
Input transient current, any pin
Short circuit immunity to VDD/AVDD or VSS/AVSS,
any output
ESD voltage immunity, Human Body Model, any pin
ESD voltage immunity, Charge Device Model, any
pin
Mechanical shock
Ambient temperature when operating
Storage temperature
Note 1:
Note 2:
Note 3:
The SPI interface consists of the 4 signals MOSI, MISO, SCLK and LOAD.
Absolute Maximum Ratings
SPI Serial Data Interface
Name
MOSI
MISO
LOAD
SCLK
Signal Definitions and Characteristics
According to AEC-Q100-002 Rev. C or JESD22-A114 Rev. F
According to AEC-Q100-011 Rev. B or JESD22-C101 Rev. D
According to MIL-STD 883E.
Signal Description
Master Out, Slave In.
After a negative edge on LOAD, 8-bit command is shifted in on MOSI, clocked by SCLK (MSB first).
Master In, Slave Out.
Output from previous command is stored in a Data Register. At a negative edge on LOAD, the
content of the Data Register is loaded to the Data Output Register. While command byte is shifted
into the Command Register, Data Output is shifted out on MISO (MSB first).
Chip Select/Transfer Start Strobe.
As long as LOAD=1, the MISO output is in a high-Z mode (tri-stated). A negative edge on LOAD
initiates an SPI transfer. The new command is executed after a positive edge on LOAD. If a positive
edge occurs on LOAD before at least 8 bits are shifted in on MOSI, the command will be ignored.
Serial Data Clock.
MOSI is read on the positive edge of SCLK, and MISO is shifted out on the negative edge of SCLK.
DATASHEET
- 6 -
Symbol
VDD, AVDD
SAR10 GYRO SENSOR SERIES
Note
1
2
3
Specifications
Min
-0.5
-0.5
-40
-55
Nom
SAR10, SAR10H
Max
7.0
VDD
+0.5
±100
10
2000
500
5000
+125
+125
Units
VDC
VDC
mA
min
V
V
g
°C
°C