The single-channel input hookup configuration (Figure 8) can not detect short circuits to secondary
sources of +24V dc or detect the loss of the switching function of the primary safety device (i.e., it
Connection to the Machine To Be Controlled
The hookup diagrams in Figures 5 through 9 show a generic connection of two safety output
channels of the Interface Module to Machine Primary Control Elements MPCE1 and MPCE2.
Figure 9. Interface Module pinouts
is not redundant) and thus this circuit typically can meet only ISO 13849-1 Category 2.
It is recommended that in all circumstances the installation of the Interface Module and its
associated primary safety device are installed to eliminate or minimize the possibility of failures and
faults that could result in the loss of the safety function(s).
Methods to eliminate or minimize the possibility of these failures include, but are not limited to:
• P hysically separating interconnecting control wires from each other and from secondary sources
• Routing interconnecting control wires in separate conduit, runs, or channels.
• L ocating all elements (modules, switches, and devices under control) within one control panel,
• P roperly installing multi-conductor cabling and multiple wires through strain-relief fittings. (Over-
• U sing positive-opening components as described by IEC 60947-5-1 installed and mounted in a
• P eriodically checking the functional integrity / safety function and training operators, maintenance
If you have any questions about your intended use, please contact a Banner applications
engineer at the numbers listed on the last page.
A Machine Primary Control Element is an electrically powered device, external to the Interface
Module, which stops the machinery being controlled by immediately removing electrical power
from the machine and (when necessary) by applying braking to dangerous motion.
of power.
adjacent to each other, and directly connected with short wires.
tightening of a strain-relief can cause short circuits at that point.)
positive mode.
personnel, and others associated with the operation of the machine to recognize and immediately
correct such failures.