QS30LDLQ BANNER ENGINEERING, QS30LDLQ Datasheet - Page 4

Photoelectric Sensor

QS30LDLQ

Manufacturer Part Number
QS30LDLQ
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Laserr
Datasheets

Specifications of QS30LDLQ

Output Current
150mA
Sensor Output
NPN/PNP
Supply Voltage Range Dc
10V To 30V
Sensor Housing
Rectangular
Sensor Input
Laser
Body Material
ABS Plastic
Supply Voltage Max
30VDC
Sensing Range Max
800mm
Brand/series
QS30
Current, Switching
150 mA
Function
Proximity
Ip Rating
IP67
Mounting Type
Threaded
Output
NPN/PNP
Primary Type
Photoelectric
Range, Measurement
800 mm
Sensing Mode
Diffuse
Technology
Photoelectric
Termination
5-Wire Connector
Voltage, Supply
30 VDC
Lead Free Status / Rohs Status
RoHS Exempt Product
QS30 Series Diffuse-Mode Laser Sensor
Sensor configuration is accomplished through TEACH-mode programming and
SETUP mode. After TEACH mode has defined the sensing parameters, SETUP mode
may be used to add an OFF-delay or change the light/dark operate status. Manual
Adjust may be used to fine-tune the thresholds (see page 7). Two push buttons,
Dynamic (+) and Static (-), or the remote wire, may be used to access and set
programming parameters.
Sensor programming may be accomplished using any of three TEACH methods. A
single switching threshold may be programmed using either dynamic (on-the-fly) or
static TEACH. In addition, Single-Point Static TEACH may be used to define a sensing
window, centered on a single taught condition. Single-Point TEACH programming
may be accomplished only statically.
The Remote Programming function may be used to program the sensor remotely or to
disable the push buttons for security. Connect the gray wire of the sensor to ground
(0V dc), with a remote programming switch connected between them. Pulse the remote
line according to the diagrams in the programming procedures. The length of the
individual programming pulses is equal to the value T:
TEACH and SETUP modes each may be exited either after the 60-second time-out, or
by exiting (cancelling out of) the process:
• In Static TEACH mode, press and hold the Static (-) button (or hold the remote line)
• In SETUP mode, press and hold both the Static (-) and Dynamic (+) buttons (or hold
4
for 2 seconds to exit. The sensor returns to RUN mode without saving any new
settings.
the remote line) for 2 seconds to exit. The sensor returns to RUN mode and saves
the current setting.
Remote Programming
Returning to RUN Mode
P/N 109027 rev. C
0.04 seconds ≤ T ≤ 0.8 seconds
Sensor Programming
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
Minneapolis, MN U.S.A.