XS1M18MA230 SQUARE D, XS1M18MA230 Datasheet - Page 153

Inductive Proximity Sensor

XS1M18MA230

Manufacturer Part Number
XS1M18MA230
Description
Inductive Proximity Sensor
Manufacturer
SQUARE D
Datasheet

Specifications of XS1M18MA230

Sensor Input
Inductive
Sensing Range
5mm
Supply Voltage Range Ac
24V To 240V
Sensor Output
NO
Peak Reflow Compatible (260 C)
No
Sensor Housing
Cylindrical
Sensing Range Max
5mm
Output Type
NO
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
10/02
Definition of Terms
The leakage or residual current corresponds to the current flowing through the sensor in the
OFF or “open” state. Important for 2 wire proximity sensors.
The voltage drop corresponds to the voltage at the proximity sensor’s terminals in the ON or
“closed” state.Especially important for 2 wire proximity sensors.
The period of time between energizing the sensor and its fully operational condition. Known
also as “warm-up” or “first-up” delay.
The maximum number of targets a proximity sensor can detect in a second, under standard
test conditions (standard EN50018, IEC 60947.5.2). Do not use for selection or design
purposes unless the geometry of the application is identical with the one in the picture.
Proximity sensor
©
1997-2002 Schneider Electric All Rights Reserved
m
Non metallic
material
XS
2m
XS
Power supply
1/2 Sn
t
Sensor output
T on
Load
Load
Output signal
V
Standard metal
target
mA
T off
Proximity Sensors
Supply
Supply
Definition of Terms
f =
(T on + T off)
1
349

Related parts for XS1M18MA230