Specifications of XS1M18MA230

Sensor Input
Inductive
Sensing Range
5mm
Supply Voltage Range Ac
24V To 240V
Sensor Output
NO
Peak Reflow Compatible (260 C)
No
Sensor Housing
Cylindrical
Sensing Range Max
5mm
Output Type
NO
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . . . . page 298
Wiring
10/02
Connector Cables
(M8 or S suffix; M12 or D suffix)
XSZCS101
XSZCS111
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
1
Connector
M8
M8 connector, N.O. and N.C. to to pin 4.
3 wire NO or NC
wire color/ connector pin
PNP
NPN
4
3
XSZB1
BN/1
BU/3
BN/1
BU/3
4
1
M12
Nano Conn., 3 pin, 2 m, straight
Nano Conn., 3 pin, 2 m, 90°
kk
BK/4 NO
BK/2 NC
BK/2 NC
BK/4 NO
3
2
Cable
Blue
Brown
Black
BU –
BN +
BK Output
8316
+
+
-
-
kk
XS Tubular, Inductive Sensors / 8 mm Diameter, DC; Economy Short Length
Specifications
Options
Note:Refer to p. 351, for target material correction coefficient Km.
Mechanical
Usable sensing range
Standard temperature range
Enclosure rating - cable
(see page 518)
Enclosure material
Max. tightening torque
Vibration resistance
Shock resistance
Standard target size (steel)
Differential (% of Sr)
Repeatability (% of Sr)
LED indicator type
Cable
Electrical
Voltage range – nominal
Voltage limit (including ripple)
Voltage drop (across switch), closed state
Maximum load current
Current consumption (no load)
On delay (max.)
Off delay (max.)
Power-up delay (max.)
Protective circuitry
Agency Listings
Description
Extended temperature range
(cable type and standard sensing distance only)
Extended cable length
Accessories
Description
Metal mounting lock nuts
Mounting bracket, plastic
Mounting bracket, diecast zinc
©
1997-2002 Schneider Electric All Rights Reserved
Shielded
Non-shielded
NEMA Type
IEC Type
Case
Sensing face
(IEC 60068.2.6)
(IEC 60068.2.27)
A
B
3 wire
Standard/Extended Range
Short circuit protection
Overload
Radio frequency immunity (RFI)
Electrostatic; transients; impulse
Reverse polarity protection
®
E164869
CCN NRKH
8 mm Diameter, DC; Economy Short Length
Standard Range
Extended Range
Standard Range
Extended Range
Standard Range
Extended Range
Standard Range
Extended Range
CR 44087
Class 3211 03
Down to -40° C (-40° F)
16.4 ft. (5 meter) cable
32.8 ft. (10 meter) cable
XS Tubular, Inductive Sensors
0 to 1.2 mm
0 to 2 mm
0 to 2 mm
-25° C to +70° C (-13° F to +158° F)
-25° C to 50° C (-13° F to 122° F)
3, 4X, 6P, 12, 13
IP67
Nickel plated Brass
PBT
5 N•m (3.7 lb-ft)
25 G, amplitude +/- 2 mm, f =10-55Hz
50 G duration 11 ms
8 mm x 8 mm
15%
3%
360° ring LED: Shows output status
One LED visible from 4 quadrants: Shows output status
27 AWG (0.11mm
12 to 24 Vdc
10 to 38 Vdc
200 mA
10 mA
0.1 ms
.2 ms
0.1 ms
.2 ms
5 ms
Yes
Yes
IEC 61000-4-3 L3
IEC 61000-4-2 L2; IEC 61000-4-4 L3; 60947.5.2 L3
Extended Range: IEC 61000-4-4 L3
Yes
2 V (2.6 V extended range)
Proximity Sensors
2
), PvR
Suffix
TF
L1
L2
Catalog Number
XSZE108
XSZB108
8316 08
225

Related parts for XS1M18MA230