NFK3-SC FLUKE NETWORKS, NFK3-SC Datasheet - Page 192

no-image

NFK3-SC

Manufacturer Part Number
NFK3-SC
Description
LAN Tester
Manufacturer
FLUKE NETWORKS
Datasheet

Specifications of NFK3-SC

Lead Free Status / RoHS Status
na
OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
1
2
3
7-40
OPEN
CONNECTED
CONNECTED
INPUT Fiber
On the Loss/Length tab in Setup, set the main and
remote testers to Smart Remote mode.
Clean the tester's and source's OUTPUT connectors and
the reference test cord connectors; then make the
connections shown in Figure 7-15.
On both testers press
T
.
Link Status
UNKNOWN
OPEN
CONNECTED
OUTPUT Fiber
F
Table 7-11. Main Tester Results for FindFiber Test (Smart Remote Mode)
, select FindFiber; then press
The main tester’s INPUT fiber path is not complete. The main tester cannot determine
the state of the OUTPUT fiber path.
The main tester’s INPUT fiber path is complete. The main tester’s OUTPUT fiber path
is not complete.
Both fiber paths are complete.
4
5
Try various connections to the patch panel with the
main tester’s INPUT fiber until the input fiber’s Link
Status shows CONNECTED.
Then try various connections with the main tester’s
OUTPUT fiber until the output fiber’s Link Status shows
CONNECTED. Table 7-11 shows the main tester results
for Smart Remote mode.